Clear-Com TWC-701 Скачать руководство пользователя страница 11

T W C - 7 0 1   A N D   T W C - 7 0 4   A D A P T O R S

1 - 5

TWC-704 CONNECTORS AND CONTROLS

The TWC-704 has no operating controls. 

The TWC-704 panel contains: 

Figure 1-3: TWC-704 Rear Connectors

1. Four 3-pin female XLR type input connectors labeled “CH B”.
2. Four 3-pin female XLR type input connectors labeled “CH A”.
3. Four 3-pin male XLR type output connectors, labeled “TW.” 
4. Four green LED “power good” indicators, labeled “PWR.” 

TWC-704 CONNECTION AND OPERATION 

1. Connect the desired two channels of standard Clear-Com intercom lines to a 

pair of female Channel A and Channel B input connectors. 

2. Connect the “TW” remote intercom stations to the corresponding male TW 

output connector. More than one station can be connected by either using the 
“loop-through” connectors on the individual stations, or by using passive 
3-pin XLR type “splitters.” 

3. The TWC-704 can supply up to 1.1 ampere of DC power before it will trip. 

After the short or overload condition is removed, the unit will automatically 
restore to normal operation. 

4. The TWC-704 internal current limit protects against short circuits. A 

short-circuit or overload on the TW line will cause the green “PWR” LED to 
go out. The internal protection will automatically recover when the short or 
overload condition is removed. 

Note:

Only Clear-Com intercom stations equipped with a TW option should 
be connected to the output of the TWC-704. If a station not equipped 
with the “TW” option is connected to the TW intercom line, the studio 
portion of channel A will be loaded down, reducing volume level and 
changing sidetone characteristics on that channel. (However, if a 
non-TW equipped station is accidentally connected to the TW line, no 
damage will be caused to the TWC-701/TWC-704 or any system 
component.) 

Содержание TWC-701

Страница 1: ...TWC 701 AND TWC 704 ADAPTORS I N S T R U C T I O N M A N U A L CLEAR COM ENCORE...

Страница 2: ...lameda CA 94501 U S A Vitec Group Communications 7400 Beach Drive Cambridge Research Park Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong An Dong...

Страница 3: ...Controls 1 3 TWC 701 Connection and Operation 1 3 TWC 704 Connectors and Controls 1 5 TWC 704 Connection and Operation 1 5 TECHNICAL SPECIFICATIONS 2 1 TWC 701 TWC 704 Adaptors 2 1 LIMITED WARRANTY 3...

Страница 4: ...T W C 7 0 1 A N D T W C 7 0 4 A D A P T O R S i i...

Страница 5: ...s combination to avoid injury from tip over 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified service personnel Servicing is...

Страница 6: ...requirement of Electromagnetic Compatibility Directive 2004 108 EC and Low Voltage Directive 2006 95 EC This device complies with Part 15 of the FCC Rules Operation is subject to the following two co...

Страница 7: ...ating power Multiple channel systems normally use separately shielded cables for individual channels This single cable or pair per channel system enables ease and flexibility of station channel assign...

Страница 8: ...s in the normal Clear Com manner Because the Clear Com call signal function is normally accomplished by applying a DC voltage to the intercom audio line call signaling is deleted from the Channel A li...

Страница 9: ...com lines to the female Channel A and Channel B input connectors 2 Connect the TW remote intercom stations to the male TW two channel output connector More than one station can be connected by either...

Страница 10: ...1 If a station not equipped with the TW option is connected to the TW intercom line the studio portion of channel A will be loaded down reducing volume level and changing sidetone characteristics on t...

Страница 11: ...al stations or by using passive 3 pin XLR type splitters 3 The TWC 704 can supply up to 1 1 ampere of DC power before it will trip After the short or overload condition is removed the unit will automa...

Страница 12: ...T W C 7 0 1 A N D T W C 7 0 4 A D A P T O R S 1 6...

Страница 13: ...Reset switch 1 Overload LED Rear Panel Controls Indicators TWC 704 4 Power LED Power Requirements TWC 701 Input Voltage 20 30 VDC Input Current idle 30mA Current Trip 1 6A Power Requirements TWC 704...

Страница 14: ...tain the accuracy of the information contained in its product manuals that information is subject to change without notice Performance specifications included in this manual are design center specific...

Страница 15: ...r UHF wireless intercom systems have a limited warranty of three years All other Clear Com and Drake brand systems and products including beltpacks have a limited warranty of two years The warranty st...

Страница 16: ...pment at VGC s expense For out of box failures use the following contact information Europe Middle East and Africa Tel 44 1223 815000 Email customerservicesEMEA vitecgroup com North America Canada Mex...

Страница 17: ...ILITY OR OTHERWISE WITH RESPECT TO THE PRODUCTS OR ANY PART THEREOF DELIVERED HEREUNDER OR FOR ANY DAMAGES AND OR LOSSES INCLUDING LOSS OF USE REVENUE AND OR PROFITS SOME STATES DO NOT ALLOW THE EXCLU...

Страница 18: ...in damage to VGC provided product This limited warranty is not transferable and cannot be enforced by anyone other than the original consumer purchaser This warranty gives you specific legal rights an...

Отзывы: