Clear-Com ProGrid PG16-FX Скачать руководство пользователя страница 20

20 

PG16-TP and PG8-TP User Guide                               

 

input acts as word clock master of the network, when present. 

 

Clock Setup: 

All devices in the network must work with the same sample rate. 

CLOCK SOURCE 

allows 

the selection of Auto (BNC priority), 

INT 

(internal)

 

or 

BNC 

(external)

 

word clock signal.  

 

Video / Ethernet setup:

  In order to use ProGrid for Ethernet transport, the option System Ethernet 

should be enabled globally. In PG16-TP and PG8-TP Local Setting it is possible to enable or disable 
Local Ethernet as well. While System Ethernet is enabled it is possible to use only the first video 
channel. Video setup can be done by allocating video input in a proper channel. This channel can be 
outputted on every device which is equipped with video output. 

Click on 

WRITE

 first, confirm with 

OK

, and then click 

CLOSE

 to exit the dialog. 

You may now connect the optical LINK cables between all ProGrid devices. 

Check your setup by connecting to any device using either RS232 or USB connection, running the OPTOCORE 
CONTROL software and starting 

ONLINE MODE

  in the 

SET

  menu. The entire network at its current state is now 

displayed in the control software. Check the 

LOG WINDOW

 for any error messages. All ProGrid devices memorize 

the current setup, even if they are switched off or disconnected from the power supply. 

Never switch on power amplifiers before the complete system is stable and the OPTOCORE CONTROL level 
meters indicate a normal level. 

Содержание ProGrid PG16-FX

Страница 1: ...PG16 TP and PG8 TP User Guide PN 399G092 Rev B 10 22 14...

Страница 2: ...e engineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambri...

Страница 3: ...Input and Output Cards 12 5 2 PG8 TP or PG16 TP with Dual Microphone 12 6 Device Details 13 6 1 A D and D A Converter 13 6 2 Analog Inputs 13 6 3 Analog Outputs 13 6 4 SANE Ports 13 6 5 AES Ports 13...

Страница 4: ...ection 17 9 8 Mains Connection 17 9 9 Hardware Connection Example 17 10 Starting Up 19 10 1 Software Installation 19 10 2 ProGrid Network Setup 19 11 Connection Tables 21 11 1 BI B Cable 22 12 Technic...

Страница 5: ...ey exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus...

Страница 6: ...y symbols Familiarize yourself with the safety symbols in Figure 1 Safety symbols These symbols are displayed on the apparatus and warn you of the potential danger of electric shock if the system is u...

Страница 7: ...6 PG8 FX and other Revolution FX devices to exchange audio channels and Ethernet All parameters on the converters can be controlled and monitored with the same software application as all other ProGri...

Страница 8: ...o four PG16 TP can be connected to the four principle ports of one PG32 AES FX enabling the exchange of 32 AES EBU signals 64 channels and control data The ports include two control data channels The...

Страница 9: ...Euroblock Phoenix connectors can be incorporated into the card slots 8 microphone inputs 8 line inputs 8 line outputs 8 microphone inputs with two independent preamps each The PG16 PG8 TP is shipped p...

Страница 10: ...nt preamps each LINE IN 8 channel line input card LINE OUT 8 channel line output card PEAK Red Overflow input level exceeds max input level of 0dBFS LEVEL Yellow Warning level input level exceeds 10dB...

Страница 11: ...onnection for remote control and update via PC LAN LINK S1 Ethernet communication is established via SANE 1 rear panel S2 Ethernet communication is established via SANE 2 rear panel LAN Ethernet commu...

Страница 12: ...Clock exchange POWER 2 Mains input for power supply 2 100 240 V POWER 1 Mains input for power supply 1 100 240 V Labels Information about card types in the slots GROUP Cards with Euroblock Phoenix con...

Страница 13: ...split if required Both ports can operate in parallel In converter mode the PG16 PG8 TP will automatically take its AES EBU signals from the port with valid incoming data with Port A having the highest...

Страница 14: ...nputs must be connected to the mains supply if possible to different phases power supply systems or even better one of them to an uninterrupted power supply UPS The power supply units operate with mai...

Страница 15: ...ser Guide 7 Control All system and device parameters are set using OPTOCORE CONTROL on a PC If the PG16 PG8 TP units are connected to a FX Device using SANE or PG32 AES FX using the BI B cables as sho...

Страница 16: ...6 16 In If 8 8 REVERSE is chosen physical channels 1 4 audio channels 1 8 of the D Sub 25 ports on the PG32 AES FX are outputs physical channels 5 8 audio channels 9 16 are inputs The PG16 AES ports a...

Страница 17: ...on directives Full metal connector hoods should be used approved acc to VDE 0871 FCC 20780 and EMC directive 2004 108 EG providing a reduction 40 dB on 30 MHz up to 1 GHz The shielding harness of the...

Страница 18: ...gue converter with a SANE network interface It possible to use AES ports which are built in each TP device to input or extract digital audio channels to from the network The configuration of the AES p...

Страница 19: ...OPTOCORE CONTROL please refer to the HELP menu of the software It is strongly recommended to familiarize yourself with the OPTOCORE CONTROL software 10 2 ProGrid Network Setup Before connecting a PG1...

Страница 20: ...cating video input in a proper channel This channel can be outputted on every device which is equipped with video output Click on WRITE first confirm with OK and then click CLOSE to exit the dialog Yo...

Страница 21: ...8 9 10 11 12 13 14 15 16 Pin 1 2 3 4 5 6 7 8 11 24 10 12 13 23 25 14 15 16 17 18 19 20 21 9 22 D Sub 25 female 13 1 25 14 Locking system acc to 4 40 UNC Pin out RS232 Port Channel RS232 Internally bri...

Страница 22: ...an AES port of an PG16 converter device a BI B cable with D Sub 25 connectors should be used PG32 AES FX Principal Port X1 X8 16 channels X9 X10 Control channels D Sub 25 male Fastening system 4 40 U...

Страница 23: ...B Gain 103 dB Conditions Reference 0dBFS 18dBu Input Output Termination 150R 300R Sample Rate 48kHz Specs noticed as typical if not otherwise stated AES Ports Convention EIA TIA 422 Channels AES EBU 2...

Страница 24: ...ncy 50 60 Hz Power consumption Depending on device 32VA Max Security classification Class 1 basic insulation connected to the protective grounding conductor Security regulations Harmonised European st...

Страница 25: ...Front panel width 483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight 2 7 kg 4 41 lbs Modifications that serve the purpose of technical improvement o...

Страница 26: ...vice may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le fonctionnement est soumis aux deux conditions...

Страница 27: ...ead it is the user s responsibility to dispose of the user s waste equipment by handing it over to a designated collection point for the recycling of WEEE The separate collection and recycling of wast...

Страница 28: ...ermine its coverage exclusions from coverage and duration EXCEPT AS SET FORTH IN THE STANDARD LIMITED WARRANTY CLEAR COM MAKES NO WARRANTIES REGARDING THE PRODUCT EXPRESS IMPLIED OR STATUTORY INCLUDIN...

Отзывы: