background image

Vitec Group Communications

Warranty

i i

Telephone for Europe, Middle East and Africa: 

+49 40 6688 4040 or 

+44 1223 815000

Telephone for the Americas and Asia:

 +1 510 337 6600

Email:

 [email protected] 

Once the standard warranty period has expired, the User Support 
Center will continue to provide telephone support if you have 
purchased an Extended Warranty. 

For latest contact information please refer to the Service and Support 
section at www.clearcom.com.

WARRANTY REPAIRS AND RETURNS 

Before returning equipment for repair, contact a User Support Center 
to obtain a Return Material Authorization (RMA). VGC representatives 
will give you instructions and addresses for returning your equipment. 
You must ship the equipment at your expense, and the support center 
will return the equipment at VGC’s expense. 

For out-of-box failures, use the following contact information: 

Europe, Middle East and Africa

Tel: +44 1223 815000  Email: [email protected] 

North America, Canada, Mexico, Caribbean & US Military  

Tel: +1 510 337 6600  Email: [email protected]

Asia Pacific & South America

Tel: +1 510 337 6600  Email: [email protected] 

VGC has the right to inspect the equipment and/or installation or 
relevant packaging.  

For latest contact information please refer to the Service and Support 
section at www.clearcom.com.

NON-WARRANTY REPAIRS AND RETURNS

For items not under warranty, you must obtain an RMA by contacting 
the User Support Center. VGC representatives will give you 
instructions and addresses for returning your equipment. 

You must pay all charges to have the equipment shipped to the 
support center and returned to you, in addition to the costs of the 
repair.  

EXTENDED WARRANTY

You can purchase an extended warranty at the time of purchase or at 
any time during the first two years of ownership of the product. The 

Содержание PRC-2

Страница 1: ...PRC 2 UHF MULTI FREQUENCY BELT PACK IFB RECEIVER INSTRUCTION MANUAL CLEAR COM WIRELESS IFB...

Страница 2: ...age Parkway Alameda CA 94501 U S A Vitec Group Communications Ltd 7400 Beach Drive IQ Cambridge Cambridgeshire United Kingdom CB25 9TP Vitec Group Communications Room 1806 Hua Bin Building No 8 Yong A...

Страница 3: ...4 Frequency Adjustment 1 4 Receiver Operating Instructions 1 6 Receiver Normal Operation already programmed 1 6 Programming Add a New Frequency To the Next Open Channel1 6 Erase All 5 Channel Memorie...

Страница 4: ...Vitec Group Communications PRC 2 UHF Multi Frequency Belt Pack IFB Receiver ii...

Страница 5: ...ng periods of time 12 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has be...

Страница 6: ...shock if the station is used improperly They also refer you to important operating and maintenance instructions in the manual Figure 1 Safety Symbols 8 hours at 90 dB SPL 4 hours at 95 dB SPL 2 hours...

Страница 7: ...gged machined aluminum package for lasting performance in abusive environments Only the PRC 2 IFB Receiver is covered in this manual The companion PTX 3 transmitter is covered in a separate manual The...

Страница 8: ...ore up to five additional frequencies accessible by pressing the knob The memory remains during power OFF and even with the battery removed The IFB PRC 2 Receiver uses 20 kHz FM deviation for efficien...

Страница 9: ...the LED is RED the battery is nearly depleted and should be replaced PROGRAMMING FUNCTIONS In the programming mode the LED will blink at a fast rate to indicate scanning for an active frequency It als...

Страница 10: ...nce phones 600 to 2000 Ohms will have an inherently lower power level due to their high impedance and likewise low impedance phones may be extremely loud CAUTION Always set the Audio Level knob to min...

Страница 11: ...Vitec Group Communications PRC 2 UHF Multi Frequency Belt Pack IFB Receiver 1 5 Figure 1 4 Frequency Adjustment Controls Figure 1 5 Frequency Adjust Figure 1 6 R1a Block Diagram...

Страница 12: ...encies have been stored in the memory change channels by pressing the knob briefly and release The LED will blink the next channel number frequency and the receiver will resume operation on that chann...

Страница 13: ...e the transmitter to another frequency and try again A second scan at high sensitivity is initiated by depressing the knob briefly at the end of the first scan to search for low level transmitter sign...

Страница 14: ...er for an hour or less Make sure your batteries are marked alkaline or lithium Short battery life is almost always caused by weak batteries or batteries of the wrong type A green LED corresponds to a...

Страница 15: ...Vitec Group Communications PRC 2 UHF Multi Frequency Belt Pack IFB Receiver 1 9 Figure 1 7 Battery Replacement...

Страница 16: ...efer to Programming Add a New Frequency on page 7 Distorted sound Transmitter gain audio level is far too high Check mod level lamps on transmitter as it is being used Refer to Operating Instructions...

Страница 17: ...Receiver antenna missing or obstructed Headphone cable is the antenna Transmitter antenna missing or obstructed Operating range too great Short range Receiver earphone cable is also the antenna Make s...

Страница 18: ...Vitec Group Communications PRC 2 UHF Multi Frequency Belt Pack IFB Receiver 1 1 2...

Страница 19: ...stal Controlled Phase Locked Loop Sensitivity 1 uV 20 dB SINAD Signal Noise ratio 95 dB A weighted Squelch quieting 90 dB AM rejection 50 dB 10 uV to 100 mV Modulation acceptance 20 kHz Spurious rejec...

Страница 20: ...proximately 8 hours operation Power consumption 60 mA Allen wrench for knob 0 035 Weight 7 3 oz with battery Size 3 6 x 2 4 x 0 8 inches housing only belt clip and knob extend beyond the housing Notic...

Страница 21: ...warranty of 90 days Headsets handsets microphones and spare parts have a limited warranty of one year UHF wireless IFB products have a limited warranty of one year UHF wireless intercom systems have...

Страница 22: ...ailures use the following contact information Europe Middle East and Africa Tel 44 1223 815000 Email SalesSupportEMEA vitecgroup com North America Canada Mexico Caribbean US Military Tel 1 510 337 660...

Страница 23: ...NOT APPLY TO YOU IN ANY EVENT TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW VGC S LIABILITY TO CUSTOMER HEREUNDER SHALL NOT UNDER ANY CIRCUMSTANCES EXCEED THE COST OF REPAIRING OR REPLACING AN...

Страница 24: ...Vitec Group Communications Warranty i v...

Отзывы: