Clear Blue Digi 2.0 Скачать руководство пользователя страница 5

Digital Screen

01
02
03

Mode

Strong

Ramp Up

Pulse

Function

Continuous full power

Light gradually ramps up from weak to strong

Light pulses at peak frequency

Initially press the on/off power button to switch the unit on. You can then select the
mode of operation. With the Clear Blue Digi 2.0, you now can select the amount of 
working time. Press the time select button “T” and scroll through the options of 5 
seconds, 10 seconds, 15 seconds or 20 seconds. During operation, the digital 
display will show the time countdown and the unit will also provide an audible beep
after every 5 seconds. You may press the on/off button during operation to 
immediately shut off the light.  

After three minutes without any operation, the unit switches to standby mode to 
conserve the battery. Press the on/off button to turn the unit back on. The Clear
Bluedigi comes with new battery warning indicators to ensure you have the proper
light strength during curing procedures. The digital screen will display LO and the 
unit will begin to beep when the battery is low and needs to be placed upon the 
base and recharged. 

Base:

When inserting the handle into the base, the LED light on the base will indicate the
status of the battery.

Содержание Digi 2.0

Страница 1: ...user s guide LED curing light For wireless unit Clear Blue Digi 2 0 digi 2 0...

Страница 2: ...Royce of batteries For many years only nickel cadmium Ni Cad batteries could be used in portable devices In 1990 nickel metal hydride Ni MH batteries became available However it is only recently that...

Страница 3: ...ever use any other battery except the original battery or a manufacturer supplied replacement battery otherwise severe damage may result 5 Don t place unit near flammable items and do not touch a flam...

Страница 4: ...battery is being charged When the light turns green charging has completed Charging time should take no longer than 4 hours for a complete charge Function Description Follow the simple directions bel...

Страница 5: ...ime countdown and the unit will also provide an audible beep after every 5 seconds You may press the on off button during operation to immediately shut off the light After three minutes without any op...

Страница 6: ...c cleaning The light rod must be cleaned and sterilized before use with each patient It can be sterilized with alcohol or it can be sterilized in an autoclave for 18 minutes at 134 C Please carefully...

Страница 7: ...harge Voltage DC3 7V Capacity 2200mAh LED Source Light Guide Rod Temperatures Power max 6W Wavelength 430 480nm Lightpower 1200mW cm2 8mm angle 60 with 360 rotatory movement autoclavable With fiber op...

Страница 8: ...Contact us with any questions or problems at 1 800 210 8945 or write to us at 618 Corporate Way Unit 1 Valley Cottage New York 10989 Revision 1 August 2017...

Отзывы: