6. Capacity

Since the DI resin filter is used at different filling locations with water 

of differing hardness, the available volume of fully desalinated 

water is also different.

The water meter and conductivity measurements are used for 

monitoring the water quality . The cartridge is exhausted when the conductivity measurement  

indicates a value of > 30 μS/cm (20 ppm). The bottle must be changed.

The quality of the supply water can be determined in various ways: 

   a) Through information provided by the water supply authority responsible (specification of the overall hardness).

   b) By measuring the mineral content using the TDS meter (4).

6.1 Maintenance and replacement of the bottles

1.  Close the supply water stopcock (1).
2.  Depressurise the system.
     Do this by opening the water outlet stopcock (2).
3. Remove the cartridge from the carriage by releasing the hose clips and hose connections (9).
4. Replacement of the resin can be organised by the specialist dealer.
5. The 50 litre replacement filter can be obtained through Cleantecs sales channels.

Note that water in the hoses escapes on disassembly!

6

Cleantecs GmbH

 

Grundweg 10

89250 Senden, Germany

 

Phone: +49 (0)7307 - 9265 0

Fax: +49 (0)7307 - 9265 20

 

Email: [email protected]

Содержание SOLA-TECS 0200272

Страница 1: ...Operating manual DI resin filter PHOTOVOLTAIC CLEANING SYSTEM BY CLEANTECS ...

Страница 2: ...t liability for the functionality of the device When it is handled in other than the usual manner When it is used for applications not specified in the manual inappropriate use When the safety instructions are not adhered to The processing filter can be damaged by Operating and installation errors Incorrectly opening the bottle Swapping over connections and hoses except by Cleantecs Independent st...

Страница 3: ... an optimum water quality for cleaning glass surfaces Any other use especially the processing of water for manufacturing foodstuffs e g beverages is regarded as inappropriate use and is prohibited The regulations of DIN1988 EN1717 apply to the installation 1 4 Operating temperatures pressures and connections The system must be protected from frost The temperature in the operating room must be at l...

Страница 4: ...ax C 30 Water temperature min C 2 Pure water quality ppm 10 3 Overall view Scope of delivery 1 Water inlet with stopcock 2 Water outlet with stopcock 3 Pressure tank resin cartridge 4 TDS measuring unit for inlet and outlet water 5 Sturdy transportation case 6 Microfilter for pre filtering 7 Microfilter for post filtering 8 Water meter 9 Quick release tank latch 1 2 3 4 5 6 7 8 9 3 ...

Страница 5: ...thout filter has been checked and therefore shows a meter reading 0 4 3 Complaints If the packaging is damaged have this verified by the supplying party Store the packaging and transport carton in a safe place in case the unit needs to be returned Complaints relating to transport damage that has not been verified by the shipping company cannot be accepted The specialist dealer must be immediately ...

Страница 6: ...e ballcock 2 and connect the hose of the high pressure cleaner to the water outlet 2 then open the pure water outlet 2 again 3 Remove the hoses and close all ballcocks for transport so that water cannot flow out of the unit Open the ballcocks to drain the water and depressurise the unit before transport 5 3 Integrated TDS measuring unit Sturdy measuring device designed for industrial applications ...

Страница 7: ...er supply authority responsible specification of the overall hardness b By measuring the mineral content using the TDS meter 4 6 1 Maintenance and replacement of the bottles 1 Close the supply water stopcock 1 2 Depressurise the system Do this by opening the water outlet stopcock 2 3 Remove the cartridge from the carriage by releasing the hose clips and hose connections 9 4 Replacement of the resi...

Отзывы: