OWNER'S MANUAL 

CL

25

00 Series 

Installation and Service Manual 

INTRODUCTION 

SPECIFICATIONS 

UNPACKING 

MOUNTING 

ELECTRICAL 

OPERATION 

MAINTENANCE 

REPLACEMENT PARTS 

TROUBLESHOOTING 

***IMPORTANT*** 

THIS MANUAL CONTAINS PRECAUTIONARY STATEMENTS RELATING TO WORKER 
SAFETY. READ AND SAVE THIS MANUAL COMPLETELY AND COMPLY AS DIRECTED. 
ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND 
EQUIPMENT ARE IMPOSSIBLE TO LIST; THEREFORE, OBTAIN THE SERVICES OF A 
PROFESSIONAL INSTALLER. A FIRE PROTECTION EXPERT SHOULD BE OBTAINED IN 
THE EVENT THE PRODUCT IS INTENDED FOR USE THAT PRESENTS A POTENTIAL 
RISK OF FIRE OR FIRE PROPAGATION. REFER TO APPROPRIATE AUTHORITIES, AND 
DISCUSS YOUR INTENDED USE WITH AIR  CLEANING SPECIALISTS, INC. WORKERS 
HANDLING EQUIPMENT OR SYSTEMS SHOULD BE INSTRUCTED TO CONDUCT 
THEMSELVES IN A SAFE MANNER. 

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

Содержание CL2500 Series

Страница 1: ...AS DIRECTED ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLER A FIRE PROTECTION EXPERT SHOULD BE...

Страница 2: ...z Single Phase 10 2 Amps Capacity CL2500 CF 2400 ACFM CL2500 CFP 1800 ACFM CL2500 CF PCO 2400 ACFM CL2500 HE 1800 ACFM Motor PSC Type 3 4hp Direct Drive with Thermal Overload Switch Two Speed Switch B...

Страница 3: ...xplosion relief vents are required on some applications Consult with an insurance underwriter or an NFPA manual to determine proper vent size ratio Dust or mist collectors must be located outdoors unl...

Страница 4: ...may apply in your particular area If there are no local requirements you should follow the National requirements If the optional Drain Plug was installed in your unit you can connect an appropriate 3...

Страница 5: ...866 455 2135 info cleanleaf com www cleanleaf com CLEANLEAF CL2500 Installation Mounting Options Option 1 Mounting w Eye Bolts Option 2 Mounting Strut Channel...

Страница 6: ...866 455 2135 info cleanleaf com www cleanleaf com Option 3 Wall Mounting w L Brackets Bolt to Mounting Bracket Bolt to Wall L Brackets should be 6 from the ends of the unit...

Страница 7: ...hen it is time to change main filter The reading may vary depending upon the contaminants Please consult your Sales Engineer for further information FILTERS All units are equipped with replaceable typ...

Страница 8: ...866 455 2135 info cleanleaf com www cleanleaf com CL2500 Wiring Diagram CL2500 w 3 Speed Switch Wiring Diagram...

Страница 9: ...OR MOUNT 5 30 2000 Two Speed SWITCH 6 30 2002 12 POWER CORD 7 30 3000 4 WAY ADJUSTABLE LOUVER CL2500 Replacement Filters ITEM PART DESCRIPTION 8 CLF 4404 24 x 24 x 4 Pleated Prefilter 9 CLF PCO Photoc...

Страница 10: ...and open all dampers if installed Check ducting for blockage if installed Check for dirty or blocked filters refer to Maintenance section Check rotation of fan Excess vibration Check structural suppo...

Страница 11: ...nameplate current rating Check motor load If the motor has manual re set thermal protector check if it has been tripped Motor may be overloaded Reduce load Increase motor size If permanent split capa...

Страница 12: ...r horsepower motor Reduce system restrictions blower Increase system restriction blower fan Motor overheats while running under load Overload Reduce load increase motor size Dirt preventing ventilatio...