Copyright ©2006 by Cleanfix Cleaning Systems Inc., 465 West Main St., Wyckoff, NJ 07481.
All rights reserved. Content is subject to change.
6
OPERATING INSTRUCTIONS
1) Connect flat hose and secure quick cam
coupler on the back of the unit. Unroll the
hose in a straight pattern to an area where
waste water is to be discharged. Make sure
there are no kinks or sharp bends that may
prevent the waste pump from working
properly.
2) Connect vacuum hose to the vacuum intake
and the wand (squeegee or extraction
wand).An additional length of vacuum hose
(max of 50 ft.) or discharge hose (max 200
ft. horizontally) may be added on to the unit
if needed.
WARNING!!! DO NOT OPERATE THIS
UNIT IN STANDING WATER.
3) Plug the unit in to a dedicated 120v, 15 amp
min circuit.
4) Turn on the VACUUM and WASTE PUMP
switches.
5) Position the wand to extract the waste
water. When the recovery tank fills up, the
waste pump will automatically discharge the
waste water.
6) WHEN THE JOB IS COMPLETED. Empty
out recovered waste into a bucket. Remove
lint bag and turn it inside out to clean. Rinse
the recovery tank with clean water. Replace
lint bag.
TROUBLESHOOTING
Symptom:
No power to the machine!
Problem:
GFCI RESET button popped out.
Solution:
Lift cover and push RESET (red) button. If the RESET button pops out immediately the
second time, do not attempt to RESET again. Have a qualified service technician check
out the machine.
Problem: Blown
fuse/circuit breaker has tripped.
Solution:
Replace fuse with the same rating. Reset circuit breaker. Make sure no other appliances
are connected on the same circuit as the machine. The machine and optional heater both
require a dedicated 15 amp circuit.
Problem:
Frayed cord, damaged plug or loose internal wiring.
Solution:
Check cord (#22027) and replace if necessary. Open switch panel and check for loose
wire connection.
Symptom:
Intermittent power to one or all of the motors/heater!
Problem:
Defective power cord
Solution:
Replace 12 ga. power cord (#12151)
Problem:
Defective switch (discolored terminal connections, burnt terminal connectors)
Solution:
Replace green lighter rocker switch (# 12027)