Troubleshooting
8. Troubleshooting
WARNING
Risk of cutting due to broken glass, metal
or other sharp edged materials!
When emptying the sweeping container,
cutting injuries may occur due to broken glass,
metal or other sharp edged materials.
•
Wear the prescribed personal protective
equipment!
CAUTION
Health impairments caused by dust
resulting from sweeping!
The inhalation of dusts can endanger the
health.
•
Wear the prescribed personal protective
equipment!
CAUTION
Risk of injury through tipping over of the
sliding bracket!
Tipping over of the sliding bracket may lead to
slight injuries, such as jamming of the finger or
haematomas in users or other persons.
•
When carrying the device, hold it so that the
sliding bracket cannot tip over.
Faults may occur even if the prescribed
maintenance work and checks of the device
before use are complied with. Possible faults are
listed in the table below, with specification of the
cause and remedy.
8.1 Fault table
Fault
Cause
Remedy
Device is
running with
difficulty or
roughly
Device is
contaminated
Clean device, see
Broom blocked
Remove blockage see
blockage”
Contaminated
broom drives
Clean broom drives,
device”
Height
adjustment
is set too
low, contact
pressure of the
plate brooms
too high
Set height adjustment,
section “Adjust height of
plate brooms”
Plate brooms do
not rotate
Contact Service
Bristles are
bent
Improper
storage
Align the bristles, see
section “Align bristles”
Sweeping
result is
insufficient
Sweeping lip is
missing, loose
or worn
Replace sweeping lip