5900S Softener Installation & Startup Guide
Page 15
www.cleanwaterstore.com
Rev 071218
Exiting the Master Programming Mode
Press the Menu/Enter Button until all steps have been viewed. The Program Mode will be exited and
normal operation resumed. If no buttons are pressed for 60 seconds or longer in Master
Programming Mode it will be exited automatically.
Start the First Regeneration
1
Close both the Inlet and Outlet valves, if not already closed. If days remaining is not already at 1
press and hold the Set/Change button. Now, press and hold the set change button again, until
the valve begins the backwash cycle and the display reads 1 – 08.
2
Start to put the valve into the service position by turning inlet the bypass knob counter-clockwise
about a quarter inch, until you can hear water passing through the bypass into the filter. Stop
and wait until you see water coming out of the drain line. It will often be mixed with air bubbles.
When you do not see bubbles anymore, keep opening the valve, a little bit at a time, stopping for
a minute or two each time. You want to see a corresponding increase in flow out of the drain line
as you increase the flow of water into the filter. After several minutes, you should have the
valve fully open.
3
Cycle Step 2, the Brine Draw, is for 60 minutes. Confirm that the water in the side tank is being
sucked down; if you start with 5 gallons, it should be empty after 15 minutes. If it is not, test
your tubing connections, and make sure the float assembly is working. Once it has sucked the
salt water into the tank, it will do a slow rinse for the rest of the cycle- a small amount of water
will be coming out of the drain line during the time.
4
Allow the valve to finish running through the last two cycles (rapid Rinse, 6 minutes and Brine
Fill, minutes determined by softener size. Open the outlet on the bypass valve and then open the
nearest treated water faucet to the unit and allow the water to run until it is clear. We advise
using a bathtub, laundry sink, or other fixture that does not have an aerator screen as any
remaining residue may get caught in the screen.
Congratulations, you are done setting up your valve!
Содержание 5900S
Страница 5: ...5900S Softener Installation Startup Guide Page 5 www cleanwaterstore com Rev 071218 ...
Страница 18: ...5900S Softener Installation Startup Guide Page 18 www cleanwaterstore com Rev 071218 Troubleshooting Guide ...
Страница 19: ...5900S Softener Installation Startup Guide Page 19 www cleanwaterstore com Rev 071218 ...
Страница 22: ...5900S Softener Installation Startup Guide Page 22 www cleanwaterstore com Rev 071218 ...