5900-BT Greensand Filter Installation & Maintenance Guide
Page 12
www.cleanwaterstore.com
Rev 112918
Next: Program Your Valve
Main Menu
1.
Remove cover by pulling out front and back tabs slightly
and lifting straight up to access control panel.
2.
Enter main menu, by pressing the
Menu/Enter
button once
(Time of day will flash)
3.
Set current time of day by pressing the
Set/Change
button
(First digit will begin to flash)
4.
To change digit value, press the
Set/Change button.
5.
To accept the digit, press the
Menu/Enter button
6.
Once the last digit for current time of day is accepted all digits will flash.
7.
With all digits flashing next press the Menu Button to set A.M. or P.M.
8.
Once A.M./P.M. is accepted the next menu item will flash
9.
To Set Number of Days Between Backwash Cycles (A) Press the Set/Change Button and
set number of days between cycles. Maximum value is 29.
10.
The recommended initial setting for the Greensand Filter is every 4 days for families or
heavy use and every 7 days for 1 to 2 persons in the home. If you experience pressure
loss or see iron in water in between backwashes, increase frequency of backwash up
to once per day.
11.
To exit menu, press the Menu/Enter button. Now the 5900-BT control will alternate
the display number of days until next regeneration and current time of day.