Operator's Manual: Models CB-1500 & CB-2500 (230V / 50 Hz)
9-4
Servicing the Metering Pump
1.
Refer to Figure 9C.
2.
Remove the pump head cover (part 1).
3.
Remove the screen (part 2) and wash it.
4.
Remove and discard the used gasket (part 3).
5.
Install a new gasket (Clean Burn Part #32422).
6.
Replace the screen and pump head cover.
Figure 9C - Servicing the Metering Pump
3
2
1
PART No 32423