A
B
Parallel Installation
E
D
Hearth Clearances
Location
Select a location for your wood heater with
great care.
*
Do not place your heater in areas of high
traffic, near furniture or draperies.
*
Check that the intended location will not
interfere with ceiling joists, rafters, valleys
and ridges.
Hearth
(Floor Protector)
Requirements
If your wood heater is to be installed on carpet,
timber or any other combustible material, you
must place a hearth (also known as a floor
protector) underneath the heater. Please
observe the following:
*
It is not recommended that you make your
own hearth
*
The hearth and heater assembly must be
placed on a firm and level surface.
Hearth Clearances
It is necessary to ensure that the heater is
positioned on the hearth so that the following
requirements are observed.
The front of the hearth should extend past the
heater door by the distance specified as D. The
side of the hearth should extend past the
heater door by the distance specified as E on
each side. The minimum width of the hearth is
specified below as F.
Heater Clearances
It is vital that the heater be installed the proper
distance from combustible surfaces like wood,
gyprock and curtains.
The diagrams show both parallel and corner
installations.
Failure to maintain these minimum distances
may result in a fire for which your insurer may
refuse to cover.
Reduced Clearances
These clearances can be reduced with proper
heat shielding. Basically a noncombustible
surface is placed between the heater and the
combustible wall. It is vital that an
unobstructed air flow be maintained between
the two surfaces to remove excess heat.
See AS/NZS 2918 for details.
200
Maxiheat Decromesh Default Flue Kit with inner & outer shields *
Model
CACS19MB (Small)
Maxiheat Decromesh Default Flue Kit with inner shield **
CACM19MB (Medium)
CACL19MB (Large)
Maxiheat Non-preforated Flue Kit with inner shield **
Maxiheat Decromesh Default Flue Kit with inner & outer shields *
Maxiheat Non-preforated Flue Kit with inner & outer shields *
All dimensions are in millimetres
E
D
C
B
A
300
225
650
250
200
300
200
550
150
200
300
200
550
150
200
300
100
450
100
Maxiheat Non-preforated Flue Kit with inner & outer shields *
INSTALLATION -
FREESTANDING HEATERS ONLY
7
200
300
225
650
250
200
300
100
450
100
C
Corner Installation
C
* Inner (MXRSISS2) and Outer (MXRSOB2) shields are required
** Inner (MXRSISS2) shield is required
NOTE:
Lower Casing location ring
2
must have 4,500mm of venting