Attach the appropriate chimney pipe lengths to the chosen chimney base plate and finish with a rain cap.
Secure the chimney with guy wires to each of the four anchors point on the furnace. Your furnace requires it’s
own chimney system and can not share a flue with another appliance.
Once you have selected a location for the furnace and connected your furnace to a chimney and a 110 volt
GFCI outlet, you will need to commence an initial firing. DO NOT connect the furnace to your duct work at this
time. Your new furnace has a protective coating of oil and paint on the surface which could produce smoke or
odors during the initial firing and will burn off. Build a small fire - DO NOT fill the firebox to it’s full capacity for the
initial burn. This initial firing allows the metals and castings to cure.
After completing the firing and allowing it to cool, you are ready to finish the installation. Refer to the remainder
of this manual for detailed instructions.
CLEARANCES
Sides of furnace, 12”; Rear of furnace, 15” (allow approximately 20”
for the return box); Front of furnace, 36”; Heat Duct, 2” for the first 9
feet then 1” thereafter.
FLUE PIPE INSTALLATION
Clearances to combustible materials will vary with the type of flue
connection used. Be sure to maintain the specified clearances for
your type of installation.
TYPE OF FLUE
REQUIRED
CONNECTION
CLEARANCE
Class A 103HT All-Fuel or Equivalent 2”
Double Wall, Stainless Steel or ....6”
Double Wall, Black Pipe w/
Stainless Steel Inner wall
24 Gauge or Heavier .................20”
Single Wall Stainless Steel or Black Pipe
The above clearances to combustibles must be maintained.
CHIMNEY REQUIREMENTS
A Class “A” HT 2100 All Fuel 6” Chimney Pipe and Base Plate should be used for the installation. See Illustration.
Place the Base Plate over the flue outlet of the furnace and drill eight(8) pilot holes into the Cabinet Top. Apply
a generous amount of high temperature sealant to the
bottom of the base plate, and around the flue outlet.
Position the base plate over the flue and secure with
the eight(8) screws provided. Then attach the flue pipe
sections.
A minimum chimney height of 6 feet is required not
including the rain cap. In order to determine proper
chimney height above the roof, measure from the side of
the chimney horizontally. As you move up the chimney,
the length increases. Once this measurement reaches 10
feet, this is the base height of the chimney. The chimney
must be 2 feet taller than the base height. If the chimney is
closer than 10 feet from the peak of the roof, the chimney
must be 2 feet taller than the peak of the roof. The 2 feet
measurement does not include the rain cap.
Once correct chimney height is achieved, check the
chimney draft. It should not exceed 0.06 inches of water
column. Then secure with three screws at each joint and
attach guy wires down to the rings located around the
top of the furnace cabinet.
See illustration.
22”
12”
20”
15”
COMBUSTIBLE WALL
COMBUSTIBLE WALL
FLUE
(TOP VIEW)
MINIMUM CLEARANCES
TO A COMBUSTIBLE
WALL
CAUTION:
DO NOT store
combustible or
flammable materials or
liquids near the
furnace.