Attach the appropriate chimney pipe lengths to the chosen chimney base plate and finish with a rain cap. 

Secure the chimney with guy wires to each of the four anchors point on the furnace. Your furnace requires it’s 

own chimney system and can not share a flue with another appliance.

Once you have selected a location for the furnace and connected your furnace to a chimney and a 110 volt 

GFCI outlet, you will need to commence an initial firing. DO NOT connect the furnace to your duct work at this 

time. Your new furnace has a protective coating of oil and paint on the surface which could produce smoke or 

odors during the initial firing and will burn off. Build a small fire - DO NOT fill the firebox to it’s full capacity for the 

initial burn. This initial firing allows the metals and castings to cure.

After completing the firing and allowing it to cool, you are ready to finish the installation. Refer to the remainder 

of this manual for detailed instructions.

CLEARANCES

Sides of furnace, 12”; Rear of furnace, 15” (allow approximately 20” 

for the return box); Front of furnace, 36”; Heat Duct, 2” for the first 9 

feet then 1” thereafter.

FLUE PIPE INSTALLATION

Clearances to combustible materials will vary with the type of flue 

connection  used.  Be  sure  to  maintain  the  specified  clearances  for 

your type of installation.

TYPE OF FLUE  

REQUIRED

CONNECTION  

CLEARANCE

Class A 103HT All-Fuel or Equivalent   2”
Double Wall, Stainless Steel or ....6”

Double Wall, Black Pipe w/

Stainless Steel Inner wall
24 Gauge or Heavier  .................20”

Single Wall Stainless Steel or Black Pipe

The above clearances to combustibles must be maintained.

CHIMNEY REQUIREMENTS

A Class “A” HT 2100 All Fuel 6” Chimney Pipe and Base Plate should be used for the installation. See Illustration. 

Place the Base Plate over the flue outlet of the furnace and drill eight(8) pilot holes into the Cabinet Top. Apply 

a generous amount of high temperature sealant to the 

bottom  of  the  base  plate,  and  around  the  flue  outlet. 

Position  the  base  plate  over  the  flue  and  secure  with 

the eight(8) screws provided. Then attach the flue pipe 

sections.

A  minimum  chimney  height  of  6  feet  is  required  not 

including  the  rain  cap.  In  order  to  determine  proper 

chimney height above the roof, measure from the side of 

the chimney horizontally. As you move up the chimney, 

the length increases. Once this measurement reaches 10 

feet, this is the base height of the chimney. The chimney 

must be 2 feet taller than the base height. If the chimney is 

closer than 10 feet from the peak of the roof, the chimney 

must be 2 feet taller than the peak of the roof. The 2 feet 

measurement does not include the rain cap.

Once  correct  chimney  height  is  achieved,  check  the 

chimney draft. It should not exceed 0.06 inches of water 

column. Then secure with three screws at each joint and 

attach guy wires down to the rings located around the 

top of the furnace cabinet.

See illustration.

22”

12”

20”

15”

COMBUSTIBLE WALL

COMBUSTIBLE WALL

FLUE

(TOP VIEW)

MINIMUM CLEARANCES 

TO A COMBUSTIBLE 

WALL

CAUTION:

DO NOT store

combustible or

flammable materials or 

liquids near the

furnace.

Содержание 1600EF

Страница 1: ... may result For your safety follow these installation instructions Contact local building or fire officials about restrictions and installation requirements in your area This furnace must be installed by a qualified technician Keep these instructions for future reference Safety Tested to UL 391 Tested Listed By Report 215 S 13b 2 Portland Oregon USA U S Environmental Protection Agency Certified to...

Страница 2: ... 31 5 8 12 COLD AIR RETURN 14 1 4 43 7 16 29 3 16 10 HOT AIR OUTLET HOT WATER COIL ACCESS OPTIONAL BLOWER SPEED SELECTOR SWITCH B D RINGS FOR GUY WIRE ATTACHMENT 17 5 16 55 5 8 5 3 16 45 3 4 65 1 2 2 9 16 29 1 2 24 1 4 6 FLUE GAS OUTLET LO MED HI ...

Страница 3: ...ing heat loss type of construction amount of insulation type of air movement the location of the unit and more importantly the duct work and return air facility Warning Do not alter this appliance in any way other than specified in these instructions Doing so may void your warranty GENERAL INFORMATION Your 1600EF furnace comes ready for installation No assembly required Unpack your furnace and ins...

Страница 4: ...uble Wall Black Pipe w Stainless Steel Inner wall 24 Gauge or Heavier 20 Single Wall Stainless Steel or Black Pipe The above clearances to combustibles must be maintained CHIMNEY REQUIREMENTS A Class A HT 2100 All Fuel 6 Chimney Pipe and Base Plate should be used for the installation See Illustration Place the Base Plate over the flue outlet of the furnace and drill eight 8 pilot holes into the Ca...

Страница 5: ...pe wrapped with weather proof UV resistant insulation The 12 inch return may be galvanized pipe and attached to the home so as to not pressurize the home NEVER reduce the 10 hot air or the 12 return air as this will result in restricted air flow and cause the furnace to not operate properly NEVER draw cold outside air into the blower housing By doing so the furnace s heat chamber will not reach th...

Страница 6: ...t you may run the hot air duct to the basement and pull the cold air return from the main floor This will create the perfect air flow since hot air rises CENTRAL DUCT CONNECTION When connecting to a central duct system avoid 90 degree elbows as this will reduce air flow delivery A duct run in excess of 40 feet is NOT RECOMMENDED The air flow and heat output will be greatly decreased Run 10 insulat...

Страница 7: ...sting furnace plenum as practical INSTALLATION 2 The baffle on this system should be made the full width of the furnace plenum in order to properly direct the air into the distribution ducts INSTALLATION 3 Extending the hot air duct from the furnace into the existing plenum will help direct the flow of air from the furnace as well as the flow in the existing furnace Ducting entering the existing p...

Страница 8: ...hten the nuts The door s gasket should be snug against the door frame on the furnace Feed Door Illustration Ash Door Illustration 1 Feed Door Latch 1 Ash Door Latch 4 1 4 20 x 3 4 Hex Bolt 4 1 4 20 Kep Nut BRACKET SHAKER GRATE HANDLE Insert the Shaker Rod into the hole on the ash door frame as shown Then attach the Shaker Bracket to the front of the furnace using two 1 4 20 x 3 4 Hex Bolts and two...

Страница 9: ...th weather resistant silicone 3 To remove the Distribution Blower E Unplug from power supply Remove items B and D as described above Unplug the blower from the top of the Fan Center G Remove the four 4 screws retaining the blower 4 To remove the Blower Motor Unplug from power supply Perform number 3 above Before removing the motor from the housing measure two things 1 The distance from the edge of...

Страница 10: ...assembly from the furnace by loosening the two bolts retaining draw band 3 To remove the motor from the tubing assembly simply loosen the set screw in the collar on the motor and slide it off the tube 4 If replacing the Flipper remove the two 8 screws retaining the plate to the tube 5 Reverse the above steps for re assembly BAFFLE BRICK REPLACEMENT If baffle replacement is necessary slide the baff...

Страница 11: ...ls of dry kindling wood 3 4 in thickness on top of paper Ignite the paper and close loading door Wait about 30 minutes until coal fire is established before adding more coal NOTE NEVER load coal over the level of firebrick Close by pass damper and set all draft controls to your own needs It may take 3 to 4 coal fires to determine how your local coal and the Clayton Furnace reacts together Adjusts ...

Страница 12: ...king place at the given settings Visible smoke consist of unburned fuel and moisture leaving your stove Learn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke EFFICIENCY Efficiencies can be based on either the lower heating value LHV or the higher heating value HHV of the fuel The lower heating value is when water leaves the combustion process as a v...

Страница 13: ...t twice monthly during the heating season to determine if a creosote build up has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire OVER FIRING Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater Whenever ashes get 3 to 4 inches deep in your firebox or ash pan and when the fire has ...

Страница 14: ...ake sure chimney flue pipe is clean and chimney is of adequate height Make sure you re not suffocating the fire with excessive amounts of unburned coal Slide baffle should be pulled out prior to load door opening 4 Distribution blower vibrating Tighten blower wheel to motor shaft Check for bad fan bearings 5 Distribution blower continues to run or will not run Check fan limit or heat sensor and ca...

Страница 15: ... 15 Wiring Diagram SERVO MOTOR ...

Страница 16: ... 16 Parts Diagram ...

Страница 17: ... Painted 25726B 1 42 Insulation Top Front 88150 1 43 Insulation Top Middle 88151 1 44 Insulation Top Rear 88152 1 45 Mount Flue Outlet 25727 891916 1 46 Weldment Cabinet Top 69648 891910 1 47 D Ring Clip 83912 4 48 Bottom Intake Painted 25722B 1 49 Assembly Cabinet Door 69649 1 50 Latch Cabinet Door 891865 1 51 1800 CFM Blower Assembly 80590 1 N S 1 4 20 x 3 4 Self Tapping Screw 83236 4 N S Washer...

Страница 18: ... void the warranty Key Description Part Qty 1 Weldment Draft Tube 68872 1 2 Spin Draft 40379 1 3 3 8 16 x 2 1 2 Carriage Bolt 83503 1 4 Lock Nut 3 8 16 83274 1 5 Actuator Motorized Draft 80592 1 6 Tube Flipper 23899 1 7 Flipper 23898 1 8 8 x 1 2 Tek Screw Hex Head 83455 2 9 Strain Relief 80154 1 10 Power Supply Cord 80593 17 in 11 Male Tyco Terminal 80382 2 Parts Diagrams And Lists Motorized Draft...

Страница 19: ... Harness 6 Circuit Receptacle 80583 1 5 Harness 3 Circuit Receptacle 80584 1 6 Harness 2 Circuit Receptacle 80585 1 7 Transformer Fan Center 80130 1 8 Strain Relief 80154 1 9 Power Supply Cord 80232 1 10 10 x 1 2 Sheet Metal Screw 83172Z 13 11 Washer Internal tooth 10 83240 1 Parts Diagrams And Lists Fan Center Control ...

Страница 20: ...emove the cover plate from the rear of the furnace firebox 4 Place one nut on each end of the water coil and thread each nut up to the end of the threads on the coil 5 Insert the coil through the holes from the inside of the firebox Install a gasket washer and nut onto each end of the water coil Tighten the nuts down securely to insure an air tight seal The installation is now ready to be plumbed ...

Страница 21: ...ghest portion of your fire bed in the center of the firebox The first flames will be long and generally orange or yellow and produce quite a bit of smoke As the gases burn off the flames become shorter change color and produce less smoke Once the fire is WELL ESTABLISHED add coal to the center of the firebox forming the cone Burning in this fashion allows heat to drive off the volatile gases and t...

Страница 22: ...stat open for a few minutes until the volatile gases have burned off It is not necessary to shake down the ashes each time you refuel the furnace Experience will be your best teacher BANKING THE FIRE For extended operation such as overnight the fire will need to be banked To do so heap coal up along the sides and back of the firebox so that the fire gradually burns it over a longer period of time ...

Страница 23: ...e 07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________________________ Stove Inspected Chimney Swept Items Replaced ________________________________ Service 02 Date _____________________ Engineer Name ________________________________ License No ______...

Страница 24: ... as a result of their breach of this written warranty or any implied warranty 2 Should the heater be replaced by United States Stove Company free of charge all further warranty obligations are thereby met 3 Parts and or service replacements made under the terms of this warranty are warranted only for the remaining period of the original heater warranty 4 Without specific written exclusionary waiver...

Страница 25: ...e place for future reference When placing an order or for warranty claims please provide the following information found on the Certification Plate located inside the cabinet door Part Number____________________________________________________________ Part Description_________________________________________________________ Model Number__________________________________________________________ Ser...

Отзывы: