Switching on the projector - Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

                                         Model                                      Firmware                              xxx (Fixture ID)                      System errors

                                                         SCENIUS                                Version X.X.X                      Dmx Address xxx                  E: .........................

                                                                                                          Date - Hour                                                                         W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address
(if set). 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

CONTROL PANEL

1

2

Dmx Address

Warning Message

Fixture ID

 

 

8

Connecting to the control signal line (DMX) - Fig. 7
Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.

Connecting to the mains supply - Fig. 6

 

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

Mains

6

7

Continue  

Содержание C61505

Страница 1: ...hers in the rich Claypaky range has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements INDEX Page Contents 2 Safety information 3 Unpacking and preparation 4 Installation and start up 5 Control panel 7 Maintenance 20 Technical information C61505 ENGLISH SCENIUS PROFILE ...

Страница 2: ...nter folgendem Link auffindbar http www claypaky it en download Ref FIS00L Safety Information Scenius INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace http www claypaky it en download Ref FIS00L Safety Information Scenius CONSIGN...

Страница 3: ...PARATION 2 x 183102 805 LAM00I fitted into fixture 1 90 9 0 9 0 9 0 LOCKED UNLOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 4 5 4 5 45 4 5 45 UNLOCKED LOCKED ...

Страница 4: ...lled on the floor resting on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base ...

Страница 5: ...y automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled CONTROL PANEL 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance...

Страница 6: ...rily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations...

Страница 7: ...eleasing Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 1 4 Turn 1 4 Turn 1 2 1 2 1 4 Turn 2 1 CLICK 10 11 MAINTENANCE Continue ...

Страница 8: ...ampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically s...

Страница 9: ...9 SCENIUS PROFILE 1 4 3 2 13 Cleaning of the filters Fig 13 Continue ...

Страница 10: ...10 SCENIUS PROFILE 1 1 4 Turn 2 3 4 14 Cleaning of the filters Fig 14 ...

Страница 11: ...11 SCENIUS PROFILE 1 2 Upper Side 1 2 Lower Side 1 2 Upper Side 15 Extraction of the effect modules Preliminary operations Fig 15 Continue ...

Страница 12: ...12 SCENIUS PROFILE 2 3 4 1 1 Lower Side Upper Side 16 Extraction of the effect modules Preliminary operations Fig 16 ...

Страница 13: ...on of the effect modules Fig 17 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 18 and 19 in reverse order Continue ...

Страница 14: ...action of the effect modules Fig 18 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 18 and 19 in reverse order ...

Страница 15: ... 19 Extraction of the effect modules Fig 19 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 15 16 17 18 and 19 in reverse order Continue ...

Страница 16: ...ean the bulb with a cloth soaked in alcohol and dry it with a clean dry cloth CAUTION Fast lamp ON OFF cycles for example 10 minutes ON 10 minutes OFF will reduce the lamp life ATT200 001 is the part number of a CP tool that could help you to take off the lamp from the fixture Lamp regulation Fig 22 To centre the lamp turn the three adjusting screws as shown in the figure Opening and closing lamp ...

Страница 17: ... max 23 mm image thickness 1 1 mm Fig 24 Before use custom gobos contact Claypaky The original gobos have a special coating designed specifically to resist to the high temperatures The rotating gobo wheel only use dichroic glass gobos it is not possible to use metal gobos For more information contact Claypaky Bearing group replacement Fig 23 23 ROTATING GOBO Continue ...

Страница 18: ...os 5 Pos 1 Pos 2 Pos 3 Pos 4 25 Replacing fixed gobos ø 31 5 mm max 23 mm image thickness max 1 1 mm Fig 25 IMPORTANT Please contact CLAY PAKY before using customized gobos Gobo orientation Fig 26 The pictures shown the correct gobos orientation 26 COATED GLASS GOBOS Grey Black side away from lamp Reflective side towards the lamp ...

Страница 19: ...emoval Fig 27 This product contains a rechargeable lithium iron tetraphosphate battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 9 1 2 5 3 4 6 7 8 LiFePO4 27 ...

Страница 20: ...ut Body Aluminum and steel structure with plastic covers Two side handles for transportation Device locking PAN and TILT mechanisms for transportation and maintenance Moving body PAN Angle Rotation 540 Fast speed 4 210 sec Normal Speed 4 958 sec PAN Resolution 2 10938 PAN FINE Resolution 0 00824 Accuracy Resolution 0 1 Range 0 2 TILT Angle rotation 268 Fast speed 2 536 sec Normal speed 3 246 sec R...