Technical information 

Type 

Output  

Voltage 

Amps 

Max surface temp. 

Measurements 

Weight

 

RCT250 

240W 

230V 

1.04 

110 

0

 

590 x 590mm 

4,7 kg 

RCT500 

500W 

230V 

2.17 

110 

0

 

1190 x 590mm 

8,5 kg 

 

 

Class 

: IPx4 Class 2 

Colour 

: White

 

 

Area of use 

The ceiling heating panel is intended for the heating of rooms requiring free walls. The panel can be used for complete heating, or as an additional heater (e.g. over a reception 

desk or other work place). There are two ratings: 240W and 500W. The heating panel provides mainly radiation heating. This implies that to obtain the same experienced 

temperature it is possible to reduce the air temperature in the room, which saves energy. Because of the low surface temperature, max 110°C, the heating panel is suitable for 

rooms with relatively low ceiling height. Thanks to the location, the panel is protected from any physical contact or damage. There is no risk of being burned. 

 

Design

 

The ceiling heating panels are approved by KEMA for two applications: 

- Ceiling mounting:  Heating cassette is directly mounted to the ceiling using the included mounting brackets. 

- Flush ceiling mounting:  Heating cassette is intended as a lay-in panel for exposed grid.  

 

Ceiling Heating Cassettes Installation Manual:

 

 

Installation 

 

- The heater(s) should only be wired by a competent electrician, and in accordance with existing national regulations. The appliance should be preceded by an all pole 

switch in accordance with existing regulations (not applicable to versions with a cord and plug). 

Mounting height above floor shall be at least 1,8 m, l

ateral distance to wall shall be at least 50 mm. (See fig A) 

- One or more units have to be connected to power line with a differential circuit breaker rated at 30 mA. The cable section has to be at least 1,5 mm2.  

- Units with cable and plug can be interconnected using appropriate connection materials.  

- The maximum power in interconnection is 2100W. If the units are to be extra insulated, then this insulation must not exceed a value of R=5 m2K/W. 

- The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction 

- Children being supervised not to play with the appliance. 

- Allow disconnection of the appliance after installation, by accessible plug or a switch in the fixed wiring, unless a switch complying with a contact separation in all poles 

of at least 3 mm. 

- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 

 

 

2. Mounting 

 

2.1 Integrated in ceiling, put in exposed grid (See fig A and B)

 

- Place the cassette in the required ceiling square. Minimum design height ”H” for dismounting, T-profile 32x15: 150 mm, T-profile 38x24: 200 mm. NOTE! Avoid fixing 

vertical  bars  in  the  T-profile  where  a  heating  panel  is  to  be  installed.  The  panel  fills  out  the  whole  square.    It  is  recommended  that  the  ceiling  frame  is  adequately 

supported. 

- Connect the panel. 

 

2.2 Bracket mounting (See fig A and C)

 

- When mounting in gypsum board, make sure that the panel frame is anchored in the beam behind. During long-term high temperatures the strength of the board is 

reduced. 

 

- Measure, drill and screw the panel frame to the ceiling.  

- Hook the panel brackets to the panel frame on the ceiling  

- Connect the panel. 

 

Fig A

                 minimum distance  

 

 

 

 

 

 

 

A:  Ceiling      80mm   

C:  Obstacle    500mm 

B:  Wall 

    50mm   

D:  Floor      1800mm 

 

 

 

 
Fig B

                integrated in ceiling 

 

 

 

Fig C

               bracket mounting 

                

 