ELECTRICAL CONNECTIONS 

These units are suitable for connection to a 230/240 Volt 50 Hz 
single-phase  AC  supply.    The  heaters  consume  3kW,  4.5kW 
respectively at 240 volts when switched to the full heat position. 
 

RAC3000 

3 kW 

12.5A 

RAC4500 

4.5 kW 

18.75A

 

Units  should  only  by  wired  by  a  competent  electrician  in 
accordance with the latest edition of the IEE wiring regulations.  
Ensure that the supply cables and circuit breakers are sufficient 
for the air curtain being installed. 
 
The appliance should be connected to the supply via a circuit in 
which there is an all-pole switch.   
 
To  gain  access  to  electrical connection the recessed grille must 
be  removed.    The  grille  is  secured  to  the  enclosure  of  the  air 
curtain via 4 cross head screws – see Figure 3.  Cable entry may 
be moved to alternative position if desired. 
 
For  safety  reasons  a  sound  earth  connection  must  always  be 
made  to  the  unit  before  it  is  put  to  use.    The  unit  should  be 
wired  in  accordance  with  IEE  Regulations  for  the  Electrical 
Equipment of Buildings. 
 

NOTE

: The unit MUST be reliably earthed. 

 

OPERATION 

All  units  are  supplied  with  a  remote  switch  that  gives  the 
following functions; On/off & two heat settings. 
 
For thermostatic control a room thermostat maybe connected. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

CONTROLS 

To switch on the appliance and operate the blower, depress the 
left-hand switch (marked “FAN”). 

 

When  the  centre  switch  only  (marked  with  a  single  bar)  is 
depressed  the  heat  output  is 

  of  full  heat.    When  the  right 

hand  switch  only  (marked  with  a  double  bar)  is  depressed  the 
heat output is 

 of full heat.  When both the centre switch and 

the  right-hand  switch  are  depressed  the  full  heat  output  is 
available. 

 

MAINTENANCE 

Always  ensure  that  the  main  external  electricity  supply  is 
switched off before attending to the servicing of your Claudgen 
Screen-Zone heater. 

 

To  obtain  best  results  from  your  heater  it  is  necessary  to  avoid 
the build up of dust and dirt within the unit and on the air inlet 
and  discharge  grills.    For  this  reason  regular  cleaning  is 
necessary,  paying  particular  attention  to  the  removal  of  dirt 
build up on the rotor blades.  A single drop of light oil should be 
applied to the motor bearing from time to time. 

 

PROTECTION (Thermal Cut-out) 

The  units  are  protected  from  overheating  in  the  event  of  fan 
failure  or  an  obstruction  of  the  free  airflow,  by  an  auto  reset 
thermal  cut  outs.    If  this  happens  the  thermal  cut  outs 
effectively  switches  off  the  appliance.  The  appliance  will  not 
operate  until  it  has  cooled  down.  If  this  fault  re-occurs  again, 
refer to ‘fault conditions’.  

 

FAULT CONDITIONS 

If the heater will not operate, disconnect it from the mains and 
arrange  for  a  certified  electrician  to  attend  to  investigate  the 
reason. 

 

TO REPLACE THE FAN HEATER ASSEMBLY 

a)

 

Remove the grille. 

b)

 

Disconnect  the  internal  wiring  from  the  main  terminal 
block. 

c)

 

Remove  the  four  nuts  and  washers  fixing  the  fan  heater 
assembly to the back of the case. 

d)

 

The  fan  heater  assembly  can  now  be  eased  forward  and 
removed from the heater case. 

e)

 

Fit replacement fan heater and reassemble in reverse order. 

 

SPARES 

It  is  essential  when  ordering  spares  or  replacement  parts  to 
state  the  model  number  and  the  serial  number  on  the  rating 
place fixed to the top of the unit. 

 

In the interest of progress the Company reserve the right to vary 
specifications  from  time  to  time  without  notice.    The  material 
listed is offered subject to the Company’s General Conditions of 
Sale, a copy of which can be obtained on request. 

 

NOTE:   DO NOT COVER any of the air inlet or outlet grills, at 
any time. 

 