44000076 Iss 02
Consort Equipment Products Ltd
Registered Office: Thornton Industrial Estate
Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172
Fax: 01646 695195
Email: [email protected]
BS EN ISO 9001 Registered Company No FM12671
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR
Heat-Zone
Fan Heater
FOR WIRELESS CONTROLS
Catalogue Numbers: HE7010RX 3kW 230/240V
PLEASE RETAIN THIS LEAFLET FOR FUTURE MAINTENANCE
MODEL
Heat-Zone is a quiet Fan Heater designed for Commercial and
Industrial situations, and is suitable for mounting on the wall.
The Heat-Zone incorporates a tangential flow fan and the unit is
designed to operate in free air conditions. It is important that
there should be no restriction on the free flow of air through the
unit. When installed the top of the heater case should be a
minimum of 200mm from the ceiling.
MOUNTING
The normal mounting height is 2.3m above the floor, although
this will depend to some extent on the situation.
The heater can be positioned to blow air at any angle, from
horizontal to vertically downwards, subject to the conditions
mentioned below. It is suggested that an angle of 45
0
is a
convenient starting point when setting up the unit.
It must always be installed with the axis of the motor horizontal.
Failure to ensure this will result in excessive bearing wear and
premature failure.
A mounting bracket is provided for mounting on a wall.
The heater should not be mounted in situations where it may be
subject to conditions of excessive humidity or the atmosphere is
corrosive.
INSTALLATION
To the unit connect a suitable length of 3 core flexible cable
(1.5mm
2
for 3kW) connected to the input terminal block.
Loosen mounting screws, allowing the mounting bracket to be
removed from the unit. Making sure that the mounting bracket
is horizontal, fix the bracket to the wall using 3 x No 8 wood
screws.
Place the unit on the mounting bracket ensuring the washers are
spaced as on diagram (a plain washer either side of the
mounting bracket).
Tighten screws to hold the unit at the required angle.
ELECTRICAL CONNECTIONS
These units are suitable for connection to a 230/240V 50Hz
single phase ac supply. The units consume 3kW of electrical
power when the fan and heater are in operation.
The unit must be connected to the supply via a double-pole
isolator switch.
For safety reasons a sound earth connection MUST ALWAYS be
made to the unit before being put to use.
To connect a supply to the heater, first remove the top cover by
unscrewing the 2 fixing screws then lifting off the cover. The
input terminal block, marked ENL, is fitted at the left hand side
of the unit looking from above (at the opposite end to the fan
motor).