C
USTOMER
H
ELPLINE
Should you need any advice on the use of your new Consort product please contact our Helpline:
Consort Equipment Products Limited
Thornton Industrial Estate, Milford Haven, Pembrokeshire, SA73 2RT
Tel: 01646 692172 Fax: 01646 695195 Email: [email protected] Web: www.consortepl.com
Operation hours: Mon to Thu 8.30am to 4.30pm | Fri 8.30am to 3.30pm
BS EN ISO 9001 Registered Company No FM12671
41000972 iss 07
4
Wiring diagram
NOTE: This unit is suitable for remote control operation,
with the use of remote control switch part no. HE8407.
The two independent feeds must be used on 6kW heat-
ers as shown on the diagram.
This optional control switch is useful if you have the unit
mounted up high, as you would need a step ladder to
reach the switches. You can fit the HE8407 lower down,
allowing you to easily change the heat settings.
Remote control—HE8407
Operation
The right hand switch connects the mains supply to the fan
motor (giving a cool airflow) and energises the heat control
switches.
Heat control HE8320
When the centre switch (marked with a single bar) is
pressed the heat output is 1.5kW. When the left-hand
switch (marked with two bars) is pressed the heat output is
3kW. When both switches are pressed the heat output is
4.5kW.
Heat control HE7426
When the centre switch (marked with a single bar) is
pressed the heat output is 3kW. When the left-hand switch
(marked with a single bar) is pressed the heat output is 3kW.
When both switches are pressed the heat output is 6kW.
NOTE: The unit MUST be reliably earthed.
To replace a switch
1.
Remove the top cover.
2.
Release the three fixings which secure the switch
bracket to the right hand side of the main case.
3.
Remove the push-on connectors, noting their position.
4.
Remove by compressing the plastic retaining tabs,
and lifting out the switch.
To replace the fan heater assembly
Remove the top cover.
Disconnect the internal wiring from the main terminal block
and earth stud.
Release the three fixings which secure the switch bracket to
the right hand of the main case.
Remove the four nuts and washers fixing the fan heater as-
sembly to the back of the case.
The fan heater assembly can now be eased forward and
removed from the heater case.
Fit replacement fan heater and reassemble in reverse order.
Spares
It is essential when ordering spares or replacement parts
to state the model number and the serial number on the
rating place fixed to the top of the unit.
In the interest of progress the Company reserve the right
to vary specifications from time to time without notice.
The material listed is offered subject to the Company’s
General Conditions of Sale, a copy of which can be ob-
tained on request.
NOTE: DO NOT COVER any of the air inlet or outlet grills,
at any time.