62
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
RPG13B
Black - Red
100.5Ω±8%
100Ω±8%
(20°C /68°F)
(20°C /68°F)
(Brand: Weiling)
(Brand: Dayang)
White - Black
64.5Ω±8%
68.5Ω±8%
(20°C /68°F)
(20°C /68°F)
(Brand: Weiling)
(Brand: Dayang)
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red
(-)Black
∞
(Several MΩ)
(+)Red
(-)Black
∞
(Several MΩ)
P
N
U
N
U
V
V
W
W
(+)Red
Содержание MROHC09AS
Страница 14: ...12 5 Wiring Diagram 5 1 Indoor Unit MWOHC09S MWOHC12S MWOHC18S ...
Страница 15: ...13 MWOHC24S ...
Страница 16: ...14 5 2 Outdoor Unit MROHC09AS MROHC12AS ...
Страница 17: ...15 MROHC18AS ...
Страница 18: ...16 MROHC24AS MROHC09AS MROHC12AS ...
Страница 19: ...17 MROHC18AS ...
Страница 29: ...27 T2 7 C 44 6 F the compressor frequency will not be limited ...
Страница 53: ...51 Take the 9k model as example P V P U ...
Страница 54: ...52 N U P W ...
Страница 55: ...53 N W N V ...