LISTINGS AND CODE APPROVALS
THE BUILDERS BOX SERIES HAS BEEN TESTED AND APPROVED IN ACCORDANCE WITH
CSA AND UL STANDARDS FOR FIXED AND LOCATION DEDICATED ELECTRIC ROOM HEATERS.
MODEL SPECIFICATIONS
WARNING
INSTALLATION OVERVIEW
(Please read all instructions and user manual before installation)
THE INSTALLATION OF THE BUILDER BOX MUST COMPLY WITH THE APPLICABLE
LOCAL AND / OR NATIONAL ELECTRICAL CODES AND UTILITY REQUIREMENTS.
THIS INSTALLATION SHOULD BE ENTRUSTED TO ONLY QUALIFIED
PERSONNNEL WHERE REQUIRED BY LAW.
Section 1.) Prepare product for installation.
Section 2.) Rough in framing following the recommended dimensions.
Section 3.) Recommended power supply wire specifications.
Section 4.) Mount the unit.
Section 5.) 120V wiring instructions.
Section 6.) 208/240V wiring instructions.
Section 7.) Install control box.
Section 8.) Check & test.
Section 9.) Electrical wiring diagram.
E-2
36EB110-GRT
36EB220-GRT
36”
TRADITIONAL
36”
CONTEMPORARY
36EB111-GRC
36EB221-GRC
MODEL NUMBER DESCRIPTION
120
120
208/240
208/240
RATED POWER
WATTS
1440
1440
2100/2800
2100/2800
12
12
10.1/11.7
10.1/11.7
BTU
AMPS
VOLTAGE
36”
TRADITIONAL
36”
CONTEMPORARY
4400
6700/8900
4400
6700/8900