LIVE CABLE
NEUTRAL CABLE
2 CONNECTORS JOIN THE 3 PHASES
ONE CONNECTORS JOIN ALL THE NEUTRAL CABLES
EARTH CABLE
NEUTRAL CABLE
ONE CONNECTORS JOIN ALL THE NEUTRAL CABLES
EARTH CABLE
LINE 1
LINE 2
LINE 3
THE H850 PASS THROUGH MACHINE
IS A 240VOLT MACHINE SO CHANGING
FROM 3 PHASE TO SINGLE PHASE ONLY
ALTERS THE HEATERS
THE WASH PUMPS ARE BOTH 240 VOLT
RATING 3 PHASE = 15 AMP PER PHASE
H850
H850
RATING SINGLE PHASE = 30 AMP
Note: H900 is a 9kw
Machine and is 3phase only
Note:
H900 can NOT be wired
as single phase machine
TWO 'C' CONNECTORS JOINING THE THREE PHASE TOGETHER
THESE ARE FOUND IN THE PLASTIC BAG INSIDE THE MACHIN ON DELIVERY
TERMINAL BLOCK
TERMINAL BLOCK
CLASSIC HYDRO 850 & 900
MAINS CABLE WIRING
WO JUNE 2001
WIRED AS SINGLE PHASE
H850 MACHINES ARE NORMALLY DELIVERED AS 3 PHASE
CHANGING FROM THREE PHASE TO SINGLE PHASE = FIT THE 2 'C' CONNECTOR TO THE 3 LIVE CONNECTIONS
FIT A 3 CORE 6MM CABLE
CHANGING FROM SINGLE PHASE TO THREE PHASE = REMOVE THE 2 'C' CONNECTORS
AND FIT 3 PHASE CABLE ( 5 CORE 2.5MM)
'C' CONNECTOR
PAGE 19