PRO-SVR_LEGACY
Page 7 of 13
Troubleshooting Guide
Symptom Possible
cause
Unit won’t turn on
Check connections;
Check fuses;
Check soft-start circuit;
Check relays;
Check power supply circuits (positive rail, negative rail)
Smoked and/or burned
components
Check for short between components and ground;
Check output transistors;
Check power supply circuits (positive rail, negative rail).
Blown fuses
Check for short between fuse and ground;
Check power supply circuits (positive rail, negative rail).
No output
Check connexions;
Check output relays;
Check power supply circuits (positive rail, negative rail,);
Check output transistors.
Unit turn into protection
Check for smoked and/or burned components;
Check power supply circuits (positive rail, negative rail,);
Check source and load;
Check protection circuit;
Check sensor wires between sensor PCB and control PCB;
Check outputs transistors and Mosfet drivers;
Perform updates, if necessary.
Excessive buzz and/or hum
Check electrical lines;
Check for a ground loop in the system.
Oscillation Check
source;
Check capacitors on main board;
Check 4.7
ƻ
resistor.
Intermittent signal
Check connections;
Replace shield wires.
Содержание CAV-180
Страница 4: ...PRO SVR_LEGACY Page 4 of 13 Block diagrams ...
Страница 14: ......
Страница 15: ...B1D9XR02 sch 1 Tue Jul 17 12 04 49 2007 ...
Страница 16: ......
Страница 17: ...B1DBXR02 sch 1 Tue Jul 17 12 01 57 2007 ...
Страница 18: ...B2E1XR00 sch 1 Tue Jul 17 12 00 17 2007 ...
Страница 19: ...B2E3XR01 sch 1 Tue Jul 17 12 00 38 2007 ...
Страница 20: ...B2E4XR00 sch 1 Tue Jul 17 12 02 42 2007 ...
Страница 21: ...B2E5XR00 sch 1 Tue Jul 17 12 01 07 2007 ...
Страница 22: ......
Страница 23: ......
Страница 24: ...B2E8XR00 sch 1 Tue Jul 17 12 06 43 2007 ...