Calibrations and Adjustments
Bias adjustment:
Note: Bias adjustment should be made without any load connected to the amplifier’s output, and no signal
connected to the amplifier’s input.
1. Connect a multimeter to R8 leads and set the multimeter to mV scale.
2. Turn trimpot RV1 counterclockwise until it reaches 0
ƻ
. A click should be heard.
3. Turn on amplifier, and let it warm up for 15 minutes on idle.
4. Adjust trimpot RV1 to get a 14mV reading.
5. Let the amplifier warm up for a 24 hours period with signal and load.
6. Remove signal and load, and reconnect the multimeter, setted to mV scale, to R8 leads. Note the
reading.
7. Connect the multimeter to R9, R10, R11 and R12 leads. Note the reading.
8. Input the results into this formula:
((120 – mV
R8
– mV
R9
– mV
R10
– mV
R11
– mV
R12
) ÷ 5) + mV
R8
9. Connect the multimeter to R8 leads, and adjust RV1 to match the reading to the formula result.
10. Results should be around 24mV.
DC offset:
Note: DC offset adjustment should be made without any load connected to the amplifier’s output, and no
signal connected to the amplifier’s input.
On these units, DC offset can’t be adjusted. Measure DC offset using a voltmeter connected to the output
posts, scale setted to mV. DC offset should be less than 10mV.
Содержание CA-301
Страница 4: ...PRO SVR_LEGACY Page 4 of 13 Block diagrams ...
Страница 14: ...B015XR06 sch 1 Tue Jul 17 11 32 18 2007 ...
Страница 15: ...B019XR02 sch 1 Tue Jul 17 11 28 08 2007 ...
Страница 16: ...B01GXR02 sch 1 Tue Jul 17 11 31 27 2007 ...
Страница 17: ...B022XR04 sch 1 Tue Jul 17 11 30 53 2007 ...
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ...B027XR05_B028XR04 sch 1 Tue Jul 17 11 29 30 2007 ...
Страница 22: ...B02AXR01 sch 1 Tue Jul 17 11 29 00 2007 ...
Страница 23: ...B1D6XR01 sch 1 Tue Jul 17 11 30 02 2007 ...
Страница 24: ...B1D8XR00 sch 1 Tue Jul 17 11 30 27 2007 ...
Страница 25: ......
Страница 26: ...B20BXR00 sch 1 Tue Jul 17 11 31 54 2007 ...