![Classe Audio 25 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/classe-audio/25/25_user-manual_2617996010.webp)
PRO-SVR_LEGACY
Page 10 of 10
Fuses
EXTRA PRECAUTIONS SHOULD BE TAKEN WHEN REPAIRING, MODIFYING, OR
TROUBLESHOOTING IN THE POWER SUPPLY AREA. UNIT MUST BE DISCONNECT
FROM MAIN SOURCE AND CAPACITORS MUST BE DISCHARGED USING A 100W
INCANDESCENT BULB.
WHEN REPLACING FUSES, PLEASE MAKE SURE THAT THE FUSE HOLDERS ARE
HOLDING THE FUSES VERY TIGHTLY. A LOOSE FUSE HOLDER CAN TRANSLATE INTO
DISTORTION ON TOP OF THE SIGNAL.
Main fuses:
For 100 – 120v units: 12A slo-blo, Classe part number MDA-12A
For 220 – 240v units: 10A slo-blo, Classe part number MDA-10A
The main fuse is located at the back of the unit, on the rear panel.
Voltage Change
EXTRA PRECAUTIONS SHOULD BE TAKEN WHEN REPAIRING, MODIFYING, OR
TROUBLESHOOTING IN THE POWER SUPPLY AREA. UNIT MUST BE DISCONNECT
FROM MAIN SOURCE AND CAPACITORS MUST BE DISCHARGED USING A 100W
INCANDESCENT BULB.
1. Set the jumper position according to the table below.
2. Replace the varistor, according to new line voltage, following Classe’s recommendations. If varistor is
not available, remove old varistor and leave it empty.
Jumper positions, main transformer
Mains
Jumper 1
Jumper 2
Jumper 3
Varistor
100VAC A
E
F
221
120VAC A
C
D
221
220VAC
B
E
-
391 / 441
240VAC
B
D
-
391 / 441