background image

clas.com

PONT ELEVATEUR 2 COLONNES ASYMETRIQUE 

AVEC SOCLE 4T
2 COLUMNS ASYMETRIC POST LIFT WITH 

BASEMENT 4T

PE 2000

Содержание PE 2000

Страница 1: ...clas com PONT ELEVATEUR 2 COLONNES ASYMETRIQUE AVEC SOCLE 4T 2 COLUMNS ASYMETRIC POST LIFT WITH BASEMENT 4T PE 2000...

Страница 2: ...ASYMETRIQUE AVEC SOCLE 4T 2 SOMMAIRE GARANTIE INTRODUCTION EMBALLAGE TRANSPORT ET STOCKAGE DESCRIPTION SECURITE INSTALLATION CALIBRATION ENTRETIEN ET MAINTENANCE IDENTIFICATION DES PANNES VENTUELLES...

Страница 3: ...onctionnement de la machine Les d penses relatives aux lubrifiants au transport aux taxes douani res la TVA et tous ce qui n a pas t pr vu dans le contrat de fourniture sont dans tous les cas la charg...

Страница 4: ...ANSPORT Sch ma standard Le fabricant se r serve le droit d apporter des modifications au manuel d utilisation et d entretien en cas d am liorations technologiques Les emballages peuvent tre soulev s e...

Страница 5: ...que et ou de surcharge en cas de panne de la pompe huile en position debout le syst me r agira pour emp cher le v hicule de tomber Equip d un cylindre colonne pour une plus grande stabilit pendant les...

Страница 6: ...PE 2000 PONT ELEVATEUR 2 COLONNES ASYMETRIQUE AVEC SOCLE 4T 6 4 DIMENSIONS DU PONT L VATEUR Figure 1 Dimensions de le pont l vateur...

Страница 7: ...geur totale l vateur Poids Tension Puissance du moteur Huile hydraulique Temp rature de service Humidit tol r e Niveau de bruit Hauteur d installation Temp rature de stockage Lieu d installation lectr...

Страница 8: ...des dommages aux personnes aux v hicules ou d autres biens caus s par une utilisation incorrecte de l quipement Pendant le levage ou la descente l op rateur doit rester dans la zone du poste de comma...

Страница 9: ...eurs et les travailleurs de la maintenance peuvent tre expos s lorsque le v hicule est en position sur le pont l vateur ainsi que les diff rents dispositifs de s curit et de protection adopt s par le...

Страница 10: ...structions fournies Pendant la mont e et la descente aucune personne n est autoris e travailler sous les parties mobiles du pont l vateur mais il faut travailler dans la zone s curis e Image 5 RISQUE...

Страница 11: ...pont fonctionne est clair e correctement et uniform ment conform ment aux lois en vigueur sur le lieu d installation RISQUE DE CHUTE DU V HICULE EN RAISON D UN MAUVAIS POSITIONNEMENT Le centre de gra...

Страница 12: ...roit situ au dessus d une pi ce vide Il est interdit d installer le pont l vateur proximit d appareils mettant de la chaleur de l eau des humidificateurs et des chemin es lectricit avant d installer l...

Страница 13: ...longueur des chevilles utilis es Connectez un c t du fil d acier travers le trou de fixation au chariot passez le c ble de l extr mit sup rieure de le pont et connectez le au chariot de l autre colonn...

Страница 14: ...ptateur de hauteur en fonction du ch ssis de votre l ve personne Voir figure 8 Installez le verrou de s curit lectromagn tique sur la colonne Ajustez l crou au pivot pour laisser le dispositif de s cu...

Страница 15: ...lette de l interrupteur de s curit entrer en contact avec la goupille de support de poulie Connectez les c bles de l interrupteur de s curit comme indiqu dans le sch ma lectrique SQ3 SQ4 Installez les...

Страница 16: ...en acier 230 et 200 aux c bles portant le m me num ro d identification l int rieur de l unit de contr le CONNEXION DU DISPOSITIF DE FIN DE COURSE Connectez les c bles 102 et 100 aux c bles portant le...

Страница 17: ...tuyaux et joints d huile pour s assurer qu il n y ai pas de d versement d huile avant toute op ration de levage Utilisez tous les bras disponibles pour soulever le v hicule en les utilisant leur empl...

Страница 18: ...e Il est recommand de v rifier r guli rement l int grit des c bles en acier si des abrasions ou des d fauts sont constat s il n est pas conseill d utiliser le pont l vateur et veuillez contacter le fa...

Страница 19: ...limentation n est pas branch sur la prise murale Le moteur tourne l envers R solution Si le moteur fonctionne en for ant le compteur avec une tige d isolation remplacez le compteur La pression de s cu...

Страница 20: ...pic maximum la vanne de purge s activera pour que l huile retourne dans le r servoir Lorsque le bouton UP est rel ch le moteur cesse de fonctionner et les chariots s arr tent Lorsque le bouton DOWN es...

Страница 21: ...PE 2000 PONT ELEVATEUR 2 COLONNES ASYMETRIQUE AVEC SOCLE 4T 21 VUE CLAT E ANNEXES...

Страница 22: ...e hydraulique 60 2 22 Courroie cha ne 2 23 Goupille 9x52mm 4 24 Bras court 2 25 Extension de bras court 2 26 Boulon hexagonal M8x12 4 27 Ecrou M8 4 N Description Qt 28 Cale 2 29 Axes diam tre 20x36 4...

Страница 23: ...Y2 Y3 KM Y0 N L N V V PS 24V 5A 24 0V L N PE 24V 0V X0 X1 X2 Y3 X3 NC X3 SB1 SB2 X1 24 0V X0 L 0V X4 0V X5 0V SQ1 X4 0V X3 0V 0V SB3 X2 YV Y3 Circuit diagram of 230V 1PH CE IC input unit IC output uni...

Страница 24: ...L 3 3 PE 2 5mm 2 2 5mm 2 0 5mm 2 N L N V V PS 24V 5A 24 0V PE L N PE 16A FU 24V 0V X0 X1 X2 Y3 X3 NC X3 SB1 SB2 X1 24 0V X0 L 0V X4 0V X5 0V SQ1 X4 0V X3 0V 0V SB3 X2 YV Y3 16A FU 16A FU Circuit diag...

Страница 25: ...de descente Fin de course inf rieur Buzzer Vanne de descente Fin de course sup rieur Fin de course inf rieur de protection Fin de course inf rieur de protection AC 23A SC 03 220V TR ON 3 380V 220V 16...

Страница 26: ...COLUMNS ASYMETRIC POST LIFT WITH BASEMENT 4T 26 SUMMARY WARRANTY INTRODUCTION PACKAGING DESCRIPTION SAFETY INSTALLATION CALIBRATION MAINTENANCE AND CARE TROUBLESHOOTINGS ANNEXES 27 28 28 29 32 36 40...

Страница 27: ...luded from warranty The expenses deriving from lubricants replacement transport charges and any customs duty VAT and any other expense not specified in the supply contract are at the purchaser s charg...

Страница 28: ...INTRODUCTION PACKAGING TRANSPORTATION Standard Schema The manufacturer reserves the right to make changes to the operating and maintenance manual if there are technological improvements Packages can...

Страница 29: ...ent of a breakdown of the oil pump during the standing position the system will react to prevent the vehicle from falling Equipped with a column cylinder for greater stability during the ascent and de...

Страница 30: ...PE 2000 2 COLUMNS ASYMETRIC POST LIFT WITH BASEMENT 4T 30 4 TECHNICAL DRAWING Picture 1 lift dimension...

Страница 31: ...Overall width Weight Voltage Machine Power Hydraulic Oil Working temperature Working Humidity Noisy level Installation Height Storage Temperature Installation place Electro hydraulic 4000kg 1890mm 126...

Страница 32: ...ncorrect and unauthorized use of the lifts During the lifting or lowering phase the operator must remain in the station control zone as shown in the diagrams As shown in the diagrams the presence of p...

Страница 33: ...to which operators and maintenance personnel can be exposed when the vehicle is in position on the lift together with the various safety and protection devices adopted by the manufacturer to minimize...

Страница 34: ...structions provided During uphill and downhill operations no person is allowed to work under the moving parts of the lift but must operate in the safe area RISK OF IMPACT Picture 10 Before starting to...

Страница 35: ...rit contenues dans ce manuel RISK OF VEHICLE FALL FOR WRONG POSITIONING Picture 12 The center of gravity of the vehicle must be located in the lift area shown in RISK OF ELECTRIC SHOCK The risk of ele...

Страница 36: ...t is above an empty room It is forbidden to install the lift near devices that emit heat water humidifiers and fireplaces Electric Power Before installing the machine make sure that you have set up th...

Страница 37: ...with the length of the used dowels Connect one side of the steel wire through the fixing hole to the trolley pass the cable from the upper end of the lift and connect it to the trolley of the other co...

Страница 38: ...hoose the height adapter according to the frame of your lift See Picture 8 Install the electromagnetic safety lock on the column Adjust the nut to the pivot to let the safety device hooks the cart the...

Страница 39: ...end of the control column Let the safety switch roller come into contact with the pulley support pin Connect the safety switch cables as shown in the circuit diagram SQ3 SQ4 Install the limit switch d...

Страница 40: ...eel cables to the cables marked with the same identification number inside the control unit CONNECTION OF THE END SWITCH DEVICE Connect the 102 and 100 cables to the cables marked with the same identi...

Страница 41: ...ximum load Check all oil pipes and joints to ensure there is no oil spill before any lifting operations Use all the available arms to lift the vehicle using them at their recommended spot The center o...

Страница 42: ...l must always reach at least the indicated minimum limit It is recommended to check the integrity of the steel cables regularly if abrasions or defects are found it is not advisable to use the lift an...

Страница 43: ...or fittings The power cable is not plugged in by the power outlet The motor turns reverse Resolution If the engine works by forcing the contactor with an isolation rod replace the contactor The safety...

Страница 44: ...he pressure exceeds the maximum peak the vent valve will activate so that the oil returns to the reservoir When the UP button is released the engine stops working and the carts stop When the DOWN butt...

Страница 45: ...PE 2000 2 COLUMNS ASYMETRIC POST LIFT WITH BASEMENT 4T 45 LIFT EXPLODED VIEW ANNEXES...

Страница 46: ...ic cylinder 60 2 22 Chain belt 2 23 Pin 9x52mm 4 24 Short arm 2 25 Short arm extension 2 26 Hexagonal bolt M8x12 4 27 M8 nut 4 N Description Qt 28 Wedge 2 29 Axles diameter 20x36 4 30 Self lubricating...

Страница 47: ...Y3 KM Y0 N L N V V PS 24V 5A 24 0V L N PE 24V 0V X0 X1 X2 Y3 X3 NC X3 SB1 SB2 X1 24 0V X0 L 0V X4 0V X5 0V SQ1 X4 0V X3 0V 0V SB3 X2 YV Y3 Circuit diagram of 230V 1PH CE IC input unit IC output unit...

Страница 48: ...3 3 PE 2 5mm 2 2 5mm 2 0 5mm 2 N L N V V PS 24V 5A 24 0V PE L N PE 16A FU 24V 0V X0 X1 X2 Y3 X3 NC X3 SB1 SB2 X1 24 0V X0 L 0V X4 0V X5 0V SQ1 X4 0V X3 0V 0V SB3 X2 YV Y3 16A FU 16A FU Circuit diagram...

Страница 49: ...Motor Fuse power supply computer board power lamp Emergency UP button DOWN button lower limit switch Buzzer Electromagnet up limit switch protection limit switch protection limit switch AC 23A SC 03 2...

Страница 50: ...ECLARATION OF CONFIRMITY Nous We CLAS EQUIPEMENTS Z A de la Crouza 73800 Chignin France DECLARONS Sous notre responsabilit que le produit DECLARE THAT Under our responsibility the following products M...

Страница 51: ......

Страница 52: ...AVEC SOCLE 4T 2 COLUMNS ASYMETRIC POST LIFT WITH BASEMENT 4T PE 2000 Si vous avez besoin de composants ou de pi ces contactez le revendeur En cas de probl me veuillez contacter le technicien de votre...