OH 0014
POMPE AIR HYDRAULIQUE 10T 1/4"
1. On the "Release" side: connect the hose of the hydropneumatic pump to the hydraulic
connection of the tool used.
2. On the "Pump" side: connect the air supply line to the Air/Hydraulic Pump. Air supply should
be 5-10 CFM at 100 PST to obtain proper operating characteristics. In addition, the air line
should be equipped with an air line filter.
3. Stepping on the "pump" end of the pedal engager the pump, producing the force necessary
to run the tool.
4. Depressing the "release" end of the pump pedal will release the pressure.
Adding Hydraulic Fluid
1. Depressurize and disconnect hydraulic hose from application.
2. With pump in it's flat and horizontal position, remove the oil filler cap located on the top
plate of the reservior.
3. Use a small funnel to fill reservior to within 3/4 (19mm) of the opening.
4. Wipe up any spilled fluid and reinstall the oil filler plug.
1. lnspect hoses and connections daily.
2. Tighten connections as needed. Use non-hardening pipe thread compound when servicing
connections.
3. Use only good quality hydraulic fluid. We recommend Mobil OTE 13M or equivalent.
When not in use or during storage:
1. Depressurize and disconnect hydraulic hoses from application.
2. Wipe clean, thoroughly.
3. Store in clean, dry enyironment. Avoid temperature extremes.
4. Shield pump with a protective cover.
Changing Hydraulic Fluid
1. For best results, change fluid once a year.
2. Dispose of fluid in accordance with local regulations.
3. Fill with a good quality hydraulic jack oil as recommended above. Reinstall vented oil filler
plug.
Lubrication
Use a light machine oil to lubricate pivot points, hinges etc.
USE
MAINTENANCE