![CLAS CH 0005 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/clas/ch-0005/ch-0005_manual_2616331009.webp)
9
CH 0005
DIRECT GAS HEATER 12kw
CH 0006
DIRECT GAS HEATER 15kw
CH 0007
DIRECT GAS HEATER 30kw
The above symbol, which you will fi nd on the product itself or on the carton,
means that this product should not be treated as household waste, but should
be taken to a waste disposal center.
By disposing of this product properly, you are helping to avoid potential
negative consequences for the environment. For more detailed information
about recycling this product, please contact your local council or waste disposal
service.
INTRODUCTION
This hot air generator is a handy liquid gas fi red heater characterized by the total exploitation of
the calorifi c power of the fuel, thanks to the thermal exchange for the direct mixing between air
and combustion products. Such a device complies with EN 1596 dated 1998 standard.
WARNING
Such a device is for industrial use. Using such a device into basements is dangerous. Since such
a device needs adequate air circulation, it should only be used in open air or rooms having an
ensured and continuous air circulation. As far as its installation is concerned, national laws in
force, technical rules, as well as law provisions concerning fi re and accident prevention must be
complied with.
MAINS CONNECTION
Before connecting to mains, be sure that the voltage and frequency are correct (230/240 V – 50
Hz). The mains connection has to be made according to the national laws in force.
Before carrying out any repair or maintenance operations, always disconnect the power supply
cable and turn off the cylinder.
FUEL AND CYLINDER POSITIONING
We recommend using only propane gas (C3H8, denomination G31) or butane (C4H10, denomination
G30), or a propane/butane mixture. In all cases the gas must be I3 category. The device is to be
set up in such a manner that no hot air is directed on to fl ammable objects (cloth, paper, wood,
fl ammable substances etc.). The gas cylinder must be placed in a safe position, behind the device.
Make sure that no object may obstruct the fan air intake .We do not recommend making use of
less than 15 kg. gas cylinders.
WARNING:
- Never use the generator without outer cover
- Only connect to supply mains equipped with an earth circuit breaker.
- Air outlet must never to be reduced/minimised for any reason whatesoever
- Generator must never be covered
- When working in open air and in temperatures under 0°C, we recommend using propane gas.