GLOW PLUG ANALYZER
SPECIFICATIONS
Measuring range:
0.00 ~ 25.0
Ω
Accuracy:
±
2%
reading
Resolution:
0.01
LED Display:
1.8 inch diagonally
Operating temperature:
0ºC ~ 50ºC (32ºF ~ 122ºF)
Operational humidity:
<70%.
Power supply:
3V (2 x 1.5V AAA Batteries)
WARNING:
Do not use this glow plug checker to measure current (Amps). Never (measure Volts)
apply voltage to this device! To do so will damage it.
This user manual tells how to use and perform the required procedures for checking the
Glow Plug. Safe and effective use of this Checker is very much dependant on the user
following the normal practices and procedures outline in this manual.
1. Ensure that the vehicle ignition is OFF, before connecting or disconnecting the glow
plug.
2. Do not disconnect the glow plug power while the engine is very hot. Allow sometime to
cool down before removing.
3. Never lay tools on vehicle battery. You may short the terminals together causing harm
to yourself, the tools or the battery.
4. Do not operate the Tester in wet or very damp environment where there is condensation.
5. Do not use the Tester for another purpose other than which is designated for.
6. Do not operate if the Tester is damaged and never disassemble the unit.
It should be checked by qualified service personnel only.
7. When not in use, keep in a safe dry place and out of reach from children.
Note: The warnings, cautions and instructions given above may not cover all the situations
and conditions that may occur. Common sense and cautions are factors that cannot be
built into this Tester, but must be adhered by operator.