9
FEATURES AND BENEFITS
•
Four-Channel, Independent buttons controlling 50 levels of output intensity.
•
Two power keys control two-channel groups: Left [
] controls Channel 1 & 2 while
the Right [
] controls Channel 3 & 4.
•
12 pre-set programs (pulse frequency, pulse width, method and massage time is
preset), 3 modes - Burst, Modulation and Conventional.
•
2 are user programmable (Conventional mode only)
•
Large LCD displays Program, Intensity, Pulse Width, Count-down Treatment Time and
Program mode.
•
Treatment timer can be set from 1 minute to 23 hours and 59 minutes. Remaining
treatment time is displayed on the LCD.
•
The unit will be automatically switched off if not in use for 4 minutes.
•
Load detection : The unit will stop ALL electrical pulse if no load is detected.
•
Fast adjust protection: The intensity will stop at level 15 to avoid user increases the
intensity too rapidly.
•
Auto shut-off: LCD display will be automatically off if no operation is detected
in 3 minutes.
•
Low battery icon [ ] will be flashing if battery voltage is below 3.5V.
•
User friendly - simply switch on, select mode, then adjust each output to obtain the
desired pain relief.
GETTING STARTED
Preparation before treatment :
1. Connect the electrode wire to each output jack on the unit securely.
2. Attach a pad to each terminal lead.
3. Using a wet towel to clean up thoroughly the area for treatment.
To Start Treatment:
1. Place the self-adhesive pads directly onto the area for treatment, above and below the
area causing pain but never on top of the bones. The pads are self-adhesive, so there is
no need for using tapes or gel.
2. Press hold [
] or [
] for 3 seconds to turn on the unit. Left button [
] controls
channel 1 & 2 and Right button [
] for channel 3 & 4. The LCD then displays the initial
default setting of treatment mode with intensity level at 0 and the timer set to 30 minutes.
3. Press [ PRG ] to select the program (refer to Table on page 14-16).
For 2 user programmable programs, please read the procedure The 2 user programmable
treatment setup at next section.
4. Press [ + ] key to start the program [ CH1 +/- och CH2 +/- ] at left side, [ CH3 +/- and
CH4 +/- ] to the right. To adjust the intensity, press the [ + ] key to increase and [ - ] key
to decrease.
5. When treatment starts, the
appear. If no load is detected, the unit will stop
and
shows on the display. You can stop the treatment by pressing [ ON/OFF ], and
appear. You can restart by pressing [ ON/OFF ] again, and need to select the intensity
again. You can also pause the treatment by pressing [
] or [
], and resume by
pressing either [ CH1+ / CH2+ / CH3+ / CH4+ ].
•
For safety reason, the intensity go back to level 1 again, and you need to adjust it again.
6. Remove the pads and wires from the unit after used.
Place them on the holder for next usage.
Note : It’s better to remove the batteries from the unit after use.
THE 2 USER PROGRAMMABLE TREATMENT SETUP
1. Press [ PRG ] repeatedly until the LCD display P-C1 or P-C2.
2. To set your program, press hold [ PRG ] for 3 seconds. A SET icon will be
displayed after ”pip-pip” sound, the pulse frequency (Hz) digit will flash.
3. When it flashes, enter your favourite pulse frequency (Hz) by pressing relative [ + /- ] to
adjust, then press [ PRG ] to confirm. To adjust the pulse width µ and the massage time
(Hr:Min), repeat the process again.
4. When finished the setting, press [
] or [
] once to exit the setup.
Note : User programmable treatment will be returned to default setting when turns-off.
ELECTRODES PLACEMENT - SUGGESTED TREATMENT SITE
– see page 18-19.
TREATMENT NOTIFICATION
The pads should be put on the area where it is painful or area around with the same direction
of nerves normally. They can also be put on the area near the spine side where nerve
mastering the area of where pain occurs.
The direction of pads can be parallel
or cross