background image

10

PROBLEM

PROBABLE CAUSE

REMEDY

The compressor will
not start, or stops
and will not start
again.

Bad connections.

Check the electrical connections.
Clean and tighten as necessary.

Replace fuse

Wait 25-20 mins before attempting
to restart

Blown fuse

Overload cutout switch
has tripped.

FAULT FINDING

Compressor does
not start.

Air receiver charged

Open drain valve to expel air.
Compressor should start again when
pressure reduces to approx. 95 psi.

Air leaking from the
pressure switch
valve when the
compressor is not
running.

Faulty non-return valve.

First drain the receiver completely
of air. Renew the non-return valve.

Air pressure from
the regulator will
not adjust.

Replace Regulator

The diaphragm within the
regulator body is broken.

The compressor
does not reach the
set pressure and
overheats easily.

NOTE: It is also possible
that you are using more
air than the compressor is
capable of delivering.

I

nlet Air Filter is blocked

Renew Oil Filler/Air Filter plug

Compressor
operating, but no
air from outlet

Renew Oil Filler/Air Filter Plug

Turn Regulator clockwise to set
required pressure

Close Drain Valve

Reconnect or replace Bleed Pipe

Inlet Air Filter Blocked

Pressure Regulator closed

Drain valve open

Bleed Pipe (from Pressure
Switch to non-return valve)
broken or disconnected

Carefully unscrew the non return
valve assembly from the vertical
hex. riser, then disassemble. Clean
or renew the rubber disk before
reassembling.

With the valve restored, start the machine with the flexible pipe disconnected to
check for leaks. If leaks persist, renew the valve assembly, otherwise reconnect
the flexible pipe.

Содержание SHHH 10

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS 0805 Model No SHHH 2 10 SHHH AIR COMPRESSOR SHHH AIR COMPRESSOR Part No 2320757...

Страница 2: ...RTS Parts clarkeinternational com SERVICE Service clarkeinternational com SPECIFICATIONS Motor 230V 50Hz 1Ph Max Pressure 8 bar 120psi Air Intake 1 1cfm 25Lpm Air Displacement 5bar 0 65cfm 18 0Lpm Ele...

Страница 3: ...of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for t...

Страница 4: ...metal parts can become quite hot during operation Take care not to touch these until the machine has cooled down 9 Always adjust the pressure regulator to the recommended setting for the particular sp...

Страница 5: ...a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequ...

Страница 6: ...ld the motor fail to start immediately it is possible that the air receiver is already full of air Check the tank pressure gauge see fig 4 If you release air by opening the air drain valve see fig 1 t...

Страница 7: ...verload so that if the motor overheats for any reason the thermal overload will trip stopping the motor Allow a period for the motor to cool down before restarting 15 20 minutes c DO NOT exceed the Du...

Страница 8: ...ccumulated in the air outlet filter by pushing the valve arrowed in Fig 6 upwards with the tank under pressure 3 When you have finished with the compressor ALWAYS open the drain valve to expel all air...

Страница 9: ...and outlet tap firmly closed ii Start compressor and check to ensure there are no leaks using soapy water on all joints Should any leak be apparent stop the compressor drain the tank and rectify the...

Страница 10: ...n the regulator body is broken The compressor does not reach the set pressure and overheats easily NOTE It is also possible that you are using more air than the compressor is capable of delivering Inl...

Страница 11: ...tact your local Clarke dealer A complete kit Model KIT 600 illustrated below is available from your Clarke dealer ideal for many applications Please quote part number 3110150 The accessories are also...

Отзывы: