13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
CHECK THE NON-RETURN VALVE (EVERY 6 MONTHS)
If the reservoir pressure decreases for no apparent reason, it is possible that the
non-return valve is leaking. To check,
1. Make sure that the reservoir is not
under pressure and the
compressor is switched OFF and
disconnected from the power
supply.
2. Examine the non-return valve,
and replace the gasket and valve
if necessary.
SPECIFICATIONS
Max Pressure
8 Bar
Voltage
230 VAC (50/60Hz)
Air Displacement
7.5 CFM
Receiver Capacity
24 L
Fuse Rating
13 A
Dimensions (L x W x H)
545 x 310 x 590 mm
Guaranteed Sound Power Level
93 dB(A)
Weight
24 kg
Please note that the details and specifications contained herein, are correct at
the time of going to print. We reserve the right to change specifications at any
time without prior notice.