5
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
INSTALLING THE PUMP
1. Remove all packaging and make sure that the pump has no visible
damage. Dispose of all packaging appropriately.
• The stepped hose adaptor supplied is
designed to be used for either screw type
hose connection or push fit.
2. Connect a suitable hose (not supplied) to the
adaptor.
• Suitable hoses are available from your local
Clarke dealer.
3. When push fitting the hose to the adaptor use
a jubilee clip to secure it.
4. Stand the pump upright on a flat surface in the
water that you want to drain.
5. Ensure the pump is positioned with adequate
space - recommended minimum base area of
20 x 20 cm and the maximum depth of any
installation - 7 metres. The pump is supplied with 10 metres of power cable.
6. Always raise and lower the pump using the lifting handle and a rope
attached to it if required. Never lift or lower the pump using the power
cable.
• The filter base inlet must be fully submerged before the pump is switched
on and the pump is standing vertical.
7. Connect the mains plug to the mains supply via a high sensitivity residual
current device (RCD) which has a tripping current of less then 30mA.
8. Switch the mains power supply on.
WARNING: CHECK THE PUMP FOR DAMAGE BEFORE USE AND DO NOT
USE IF DAMAGED IN ANY WAY.
WARNING: THE WATER SEAL CONTAINS LUBRICANT WHICH IS NON-TOXIC
BUT WHICH MAY ALTER THE CHARACTERISTICS OF THE WATER IN THE CASE
OF PURE WATER, IF THE PUMP WERE TO DEVELOP ANY LEAKS.