2
WELDER SPECIFICATIONS
PRIMARY or INPUT POWER DATA
Primary Volts
230V / 1PH
Primary Amps
16 Amps
Frequency
50Hz
SECONDARY or OUTPUT POWER DATA
Sec. Volts
18 - 28 V
Max. Sec. Amps
150 Amps
USABLE WIRE SIZES
Mild Steel Wire
0.6-0.8mm
Stainless Steel Wire
0.8mm
Aluminium Wire
0.8mm
USABLE GASES MAIN USES
75% Argon 25% CO2
-
Thin Sheet Metal, Mild Steel
100% Argon
-
Welding Aluminium, Stainless Steel
100% CO2
-
Mild Steel
This model is covered by
regulations EN 60974-1 and
EN 50199, where the Duty
Cycle (X) is expressed as a
percentage of time the
machine may be used in a
given period for a specified
welding current.
i.e. When welding at 75
Amps the machine may be
used for 6 minutes (60%) in
any 10 minute period..
............or, the machine may
be used continuously,
(100%) when welding at 55
Amps
Interpolate for other
welding currents
DUTY CYCLE
Please note that the details and specifications contained herein, are correct at the time of
going to print. However, CLARKE International reserve the right to change specifications at any
time without prior notice. ALWAYS CONSULT THE MACHINE’S DATA PLATE
Содержание MIG 160TM
Страница 1: ...MIG 160TM OPERATING MAINTENANCE INSTRUCTIONS 0108 Part No 6015530...
Страница 24: ...24 PARTS DIAGRAM...
Страница 27: ...27 WIRING DIAGRAM...