Clarke HSE Series Скачать руководство пользователя страница 4

4

PUMP SAFETY INSTRUCTIONS

1. Only use the pump in the manner and for the functions described in these

instructions.

2. These pumps are designed to pump water only. Never use for pumping

flammable liquids or corrosive chemicals of any kind.

3. Never allow the pump to run dry. Switch the pump OFF immediately the

task is completed.

4. An approved Residual Current Device (RCD) must be used when pumping

from ponds or swimming pools.

5. The submersible pump may only be used for pumping water from a

swimming pool when there is no person or animal in the pool.

6. Do not attempt to carry out any repairs on the pump until it is unplugged

from the power supply.

7. Always

 

lift the pump using the handle with rope or chain attached if

necessary. Never lift or carry the pump by the power cable or by the float
switch cable.

8. Always

 

disconnect the pump from the electrical supply before placing it

into, or removing from the water, and before any cleaning or
maintenance of the pump.

9. Remember, the operator or user is responsible for accidents or hazards

occurring to other people or their property.

10. Do not install the pump on sand, silt or mud which is likely to shift or

collapse.

11. If the electrical cable becomes damaged, it must be replaced, - not

repaired.

12. Keep the work area well lit. Dark areas invite accidents.

13. Do not over-reach. Keep your proper footing and balance at all times

when handling the pump in waterlogged areas.

14. Store the pump out of the reach of children and do not allow persons

unfamiliar with these instructions to operate the pump.

15. Do not abuse the electrical cable. Never use the cable for pulling or

unplugging the pump  Damaged or tangled cables increase the risk of
electric shock.

16. Check the pump for damage before use. Any damaged part should be

inspected to ensure that it will operate properly and perform its intended
function.  Any damage should be properly repaired or the part replaced.
If in doubt, DO NOT use the appliance. Consult your local dealer.

17. When operating outdoors, use an extension cable suitable for outdoor

use.

 

Using the correct cable reduces the risk of electric shock.

Содержание HSE Series

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS HSE RANGE GC0514 SUBMERSIBLE PUMPS...

Страница 2: ...lace of purchase no product can be returned to us without prior permission This guarantee does not affect your statutory rights ENVIRONMENTAL PROTECTION RECYCLING Do not dispose of this product with g...

Страница 3: ...OTECTION 2 SPARES SERVICING CONTACTS 2 TABLE OF CONTENTS 3 PUMP SAFETY INSTRUCTIONS 4 ELECTRICAL CONNECTIONS 5 OVERVIEW 7 OPERATION 9 CLEANING MAINTENANCE 11 FAULT FINDING 12 PARTS LISTS SPARES DIAGRA...

Страница 4: ...the pump 9 Remember the operator or user is responsible for accidents or hazards occurring to other people or their property 10 Do not install the pump on sand silt or mud which is likely to shift or...

Страница 5: ...tor On no account must a 230V 13amp plug be used NOTE If a portable 110V transformer is used make sure it has a rated capacity sufficient to take the load of the pump In the event that the pump is har...

Страница 6: ...e thrown away if it is cut from the cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 Replacement fuse...

Страница 7: ...corrosive explosive or dangerous liquids The range includes models 130 200 300 301 360 361 and 650 651 as itemised in the Technical Specification on page 16 The HSEC650 HSEC651A are fitted with a tung...

Страница 8: ...d for pumping drinking water as there is a remote possibility of water contamination due to leakage of pump lubricant should the pump malfunction or the oil seal become damaged All HSE pumps are provi...

Страница 9: ...est diameter hose available as any restrictions will reduce capacity and put further strain on the motor The outlet hose diameter for each HSE pump is given in the Technical Specification on page 16 4...

Страница 10: ...s are fitted with automatic thermal overload protection If the pump overheats due to an obstruction in the pump or pumping warm water for example it will shut off automatically Switch the pump OFF and...

Страница 11: ...eaves or other debris Do not attempt to repair the pump yourself as you may damage the waterproof seal and invalidate your guarantee Repairs must be carried out by your CLARKE dealer or contact the CL...

Страница 12: ...e d r e t a w f o t n u o m a n i g n i g g u l p y b s e m i t l a r e v e s p o t s d n a t r a t S d e k c o l r i a s i p m u P p m u p n i t n e v d e g g o l c r o f k c e h C e l b a c g n i g...

Страница 13: ...c a p a C 5 1 0 3 1 G H 5 r o t a t S 5 0 0 3 1 G H 6 1 g n i k c a P p a C 6 1 0 3 1 G H 6 g n i r a e B r e w o L 6 0 0 3 1 G H 7 1 g n i R O 7 1 0 3 1 G H 7 e t a l P l a e S 7 0 0 3 1 G H 8 1 g n...

Страница 14: ...09 HG30109 HG36009 HG36109 10 Seal Cover HG20010 HG30010 HG30110 HG36010 HG36110 11 Impeller HG20011 HG30011 HG30111 HG36011 HG36111 12 Pump Casing HG20012 HG30012 HG30112 HG36012 HG36112 13 Strainer...

Страница 15: ...i w S t a o l F 6 6 0 A 0 5 6 G H 6 0 A 1 5 6 G H r e v o C l a e S 9 1 9 1 A 0 5 6 G H 9 1 A 1 5 6 G H e l b a C r e w o P 7 7 0 A 0 5 6 G H 7 0 A 1 5 6 G H e t a l P l a e S 0 2 0 2 A 0 5 6 G H 0 2...

Страница 16: ...h t g n e l e l b a C 0 1 0 1 0 1 0 1 0 1 g n i t a R P I 8 6 P I 8 6 P I 8 6 P I 8 6 P I 8 6 P I m d a e H x a M 7 8 0 1 2 1 5 9 n i m L e t a R w o l F x a M 0 4 1 0 0 2 0 0 3 0 6 3 0 9 2 H x W x L...

Страница 17: ...17 DECLARATION OF CONFORMITY...

Страница 18: ...18 DECLARATION OF CONFORMITY...

Страница 19: ...19 DECLARATION OF CONFORMITY...

Страница 20: ......

Отзывы: