Clarke HIPPO-3 Скачать руководство пользователя страница 3

3

ELECTRICAL CONNECTIONS

230V

 models should have their mains lead connected to a standard 230Volt (50Hz)

electrical supply through an approved plug or a suitably fused isolator switch.

110V 

models should have their mains lead connected to a suitable 110V supply (50Hz)

through an approved plug or suitably fused isolator switch, or to a suitable portable 110V
transformer.

We recommend that these pumps be fitted with a Residual Current Device (RCD).

If the pump is to be connected to an outdoor electrical supply, make sure that both the
plug and the socket are of a BS approved waterproof design.

In the event that the pump is hard wired into the electrical system, it must be carried out
in accordance with IEE regulations.

If used for draining swimming pools or ponds, the pump MUST be fitted with a Residual
Current Device (RCD), with a rated residual operating current of no greater than 30mA.

WARNING: THIS APPLIANCE MUST BE EARTHED

230V only

IMPORTANT: The wires in the mains lead are coloured in accordance with the following
code:

Green & Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the coloured
markings identifying terminals in your plug proceed as follows:

Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or

Earth symbol “      “ or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to plug terminal marked with a letter “L” or coloured RED

Connect BLUE cord to plug terminal marked with a letter “N” or coloured BLACK

FUSE RATING

The fuse in the plug for this appliance must be rated at 13 amps.

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-
rewirable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a danger of
electric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most electrical
outlets

5.

The fuse in the plug must be replaced with one of the same rating (13 amps) and
this replacement must be ASTA approved to BS1362.

IMPORTANT:If you are in any doubt regarding electrical installation, you should

consult a qualified electrician.

Содержание HIPPO-3

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS 6 97 SUBMERSIBLE WATER PUMPS Model Nos HIPPO 3 and 3A...

Страница 2: ...tampered with in any way or not used for the purpose for which it is intended The reason for return must be clearly stated This guarantee does not affect your statutory rights Please note that disman...

Страница 3: ...rs of the flexible cord of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a l...

Страница 4: ...ater level falls so will the float switch until it stops the pump Float switches are factory set to provide the correct ON OFF switching mode however you can adjust the level at which the pump cuts ou...

Страница 5: ...e mains supply If the unit is hard wired ensure the circuit breaker is open Check the pump installation regularly to ensure the base inlet is clear of leaves or other debris If the pump has been used...

Страница 6: ...PUMP WILL START BUT NOT PUMP 1 Water level too low below the minimum suction level Manual type 2 Check to ensure strainer is not blocked 3 Discharge tube clogged or obstructed 4 The head may be too gr...

Страница 7: ...CCESSORIES Part No 1 1 1 4 x1 1 4 BSP Outlet Elbow See your dealer 2 O Ring for Elbow LDP1200009 3 1 BSP Multi Hose Adapter See your dealer 4 O Ring for Multi Hose Adapter LDP1200002 5 1 Hose Delivery...