16
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
The
machine
does not
suck in
detergent.
Tank empty.
Fill the tank.
Lance handgrip on high
pressure setting (if
present).
Move it to the low pressure setting by
pulling the lever towards the nozzle.
Transparent suction pipe
damaged or
disconnected.
Reconnect the pipe. If the problem
persists contact an authorised service
centre.
Turning on
the burner
switch the
boiler
doesn’t
start.
No fuel.
Check the level in the tank and check
whether the rigid suction pipe is clean.
Fuel filter is clogged.
Contact an authorised service centre.
Fuel pump is either
blocked or burnt out.
Contact an authorised service centre.
Damaged thermostat.
Contact an authorised service centre.
Ignition spark insufficient
or totally lacking.
Contact an authorised service centre.
The space among the
electrodes is not correct.
Contact an authorised service centre.