Specifications

Outlet

Outlet

Max

Motor

Weight

Model

Voltage

Inches

L/Min

Head M

HP

KG

Part No

GSE1

230vac

1”

180

9.5

0.5

20

7230070

GSE1A

230vac

1”

180

9.5

0.5

20

7230071

GSE150

230vac

1½”

280

17

0.8

24

7230072

GSE150A

230vac

1½”

280

17

0.8

24

7230073

GSE2

230vac

2”

500

10

0.8

30.5

7230074

GSE2A

230vac

2”

500

10

0.8

30.5

7230075

GSE2

110vac

2”

500

10

0.8

30.5

7230076

GSE2A

110vac

2”

500

10

0.8

30.5

7230077

NOTE ‘A’ = Models with automatic float switch.

Features

Continuously rated, fitted with overload protection.

Corrosion resistant stainless steel casing.

Cast iron impeller and base for long and reliable service.

Contents

Guarantee ...................................................................................... 2

Specifications .................................................................................. 3

Safety Precautions .......................................................................... 4

Electrical Connections ................................................................... 5

Operation ........................................................................................ 6

Maintenance/Troubleshooting ..................................................... 7

Parts GSE1 & GSE1A ................................................................ 9 & 10

Parts GSE 150 & GSE150A ................................................... 11 & 12

Parts GSE2 & GSE2A ............................................................. 13 & 14

GSE 1/1A

GSE 150/150A

GSE 2/2A

Parts List 

(GSE 150 &150A)

INDEX

PART NUMBER

DESCRIPTION

QTY

1

GM8355

10MT Cable With Plug

1

2

GM8221

Inox Handle

1

3

GM8185

Inox Nut

2

4

GM8235

Condenser 16 MY

1

5

GM7093

Superior Flange

1

6

GM7105

‘O’ Ring 107.7 x 1.78

2

7

GM7111

Bearing 6203

2

8

GM8113

Motor

1

9

GM8269

Inox Screw

4

10

GM7097

Inox Washer

4

11

GM5507

Pump Body

1

12

GM7109

Flexolite Gasket

1

13

GM7084

Bracket

1

14

GM6062

Gasket

1

15

GM7103

Brass Nut

1

16

GM7247

Base

1

17

GM7086

Impeller

1

18

GM5442

Inox Screw

3

19

GM7147

Counterface

2

20

GM7153

Mechanical Seal

2

21

GM7117

Tap 1/8”

2

22

GM6048

‘O’ Ring 2037-110

2

23

GM7098

Inox Screw

4

24

GM7106

‘O’  Ring 4512

2

25

GM7092

Inferior Flange

1

26

GM7156

Inox Carter For GSE 150

1

26A

GM7157

Inox Carter For GSE 150A

1

27

GM7137

Float Switch (GSE 150A)

1

28

GM7107

‘O’ Ring 2.9 x 1.78

4

29

GM7113

Screw

4

30

GM6429

Gasket

1

31

GM6705

Flange For Cable Connection

1

32

GM7123

Stop Cable

1

33

GM7099

Inox Screw

1

34

GM7144

Inox Nut

1

35

GM7875

Cable-Lock

1

36

GM7876

Cable-Lock For Float Switch

1

37

GM1035

Connection 1” x 40

1

38

GM1095

Nipple From 1/2” to 1-1/2”

1

Please note that the details and specifications contained herein are correct at the time of going to

print. However CLARKE International reserve the right to change specifications at any time without

prior notice. Always consult the machines data plate

Содержание GSE RANGE

Страница 1: ...GSE RANGE SUBMERSIBLE PUMP SUBMERSIBLE PUMP OPERATION MAINTENANCE INSTRUCTIONS 1102...

Страница 2: ...Inox Screw 3 19 GM6774 Filter 1 20 GM7147 Counterface 2 21 GM7153 Mechanical Seal 2 22 GM7117 Tap 1 8 2 23 GM6048 O Ring 2037 110 2 24 GM7098 Inox Screw 4 25 GM7106 O Ring 4512 2 26 GM7092 Inferior Fl...

Страница 3: ...CLARKE Submersible Pump These pumps are ideal for draining ponds pools and building excavations these heavy duty pumps can handle small solids in suspension Before using the device please read this ma...

Страница 4: ...235 Condenser 16 MY 1 5 GM7093 Superior Flange 1 6 GM7105 O Ring 107 7 x 1 78 2 7 GM7111 Bearing 6203 2 8 GM8113 Motor 1 9 GM8269 Inox Screw 4 10 GM7097 Inox Washer 4 11 GM5507 Pump Body 1 12 GM7109 F...

Страница 5: ...run the pump with the body exposed for longer than 10 minutes NEVER install the pump on sand silt mud or ground that is likely to shift NEVER Lift the pump by the mains cable or the float switch cable...

Страница 6: ...Never use the plug without the fuse cover fitted 3 Should you wish to replace a detachable fuse carrier ensure that the correct replacement is used as indicated by marking or colour code 4 Replacemen...

Страница 7: ...umping warm water for example it will shut off automatically Switch the pump off and isolate from the main electric supply check for blockages and remove allow the motor to cool down before attempting...

Страница 8: ...be jammed against side wall or prevented from moving 2 Water level too low float switch in OFF position lift float to check switch B Pump Will Start But Not Deliver 1 Check to ensure base is not bloc...