Clarke GRH15 Скачать руководство пользователя страница 2

2

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INTRODUCTION

Thank you for purchasing this CLARKE heater.

This portable gas radiant heater is designed to give safe, efficient and reliable 
operation and is for use with 

Propane Gas only.

 Propane gas bottles are 

readily available from builders merchants or gas suppliers.

The heater intended for drying and the warming of commercial/industrial 
buildings where adequate ventilation is provided.

• It must always be operated as prescribed in this manual.

• It is not intended for domestic use or for the heating of habitable areas.

• It is not intended to be used to reach and maintain a certain level of 

human thermal comfort within an enclosed space.

• It is not intended to be used in enclosed areas with restricted ventilation.

• It is not for use in areas with high levels of fluctuating drafts.

• It is not intended for warming animals or live stock.

• We recommend the use of a carbon monoxide detector.

As with any equipment, optimum performance will only be achieved if the 
correct application and servicing procedures are followed.

Proper combustion depends upon correct air flow and the heater must not be 
modified or operated with parts removed or missing. Likewise, safety systems 
must not be circumvented or modified in order to operate the heater.

Before attempting to use this product, please read this manual thoroughly and 
follow the instructions carefully. In doing so you will ensure the safety of yourself 
and that of others around you and you can look forward to your purchase 
giving you long and satisfactory service.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 
months from the date of purchase. Please keep your receipt which will be 
required as proof of purchase.

This guarantee is invalid if the product is found to have been abused or 
tampered with in any way, or not used for the purpose for which it was 
intended.

Faulty goods should be returned to their place of purchase, no product can 
be returned to us without prior permission. This guarantee does not effect your 
statutory rights.

Содержание GRH15

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC1019 ISS 1 PORTABLE GAS RADIANT HEATER MODEL NO GRH15 PART NO 6920018...

Страница 2: ...a carbon monoxide detector As with any equipment optimum performance will only be achieved if the correct application and servicing procedures are followed Proper combustion depends upon correct air...

Страница 3: ...not to be used for the heating of habitable areas of domestic premises Refer to national regulations 9 Position the heater such that it is not directly exposed to water spray rain and or dripping wate...

Страница 4: ...igh altitude are more likely to be effected by Carbon Monoxide CO can build up in a confined space and failure to provide adequate ventilation can be fatal The early symptoms of carbon monoxide poison...

Страница 5: ...return Properly trained service people must repair any leaks check for further leakages and then re light the heater for you 8 IF YOU SMELL EVEN A SMALL AMOUNT OF GAS CONTACT YOUR FIRE DEPARTMENT DO N...

Страница 6: ...This heater is designed to operate with a minimum 20 pound 9 kg propane bottle Note that less gas is vaporised at lower temperatures Your local propane gas dealer will help you select the proper gas...

Страница 7: ...on a hard level surface to minimize the risk of accidental tipping The propane gas cylinder should be adequately restrained if needed Only operate this heater with the supply cylinder in the upright...

Страница 8: ...lator to the gas cylinder ensuring the cylinder connection is perfectly clean Blow out with compressed air if necessary to blast away any dust or dirt Use eye protection when working with compressed a...

Страница 9: ...e hand wheel anti clockwise when you need to start the flow of gas Ensure that you turn the cylinder off when not in use 7 In order to reduce the risk of icing up when operating for long periods at ma...

Страница 10: ...et the burner at the required angle to project the heat forward as shown LIGHTING THE HEATER 1 Ensure that the gas is correctly connected and leak free Turn on the gas supply at the bottle and at the...

Страница 11: ...gas supply line has been used it may be necessary to bleed trapped air out of the supply line before lighting Open the shut off valve and listen for the gas passing through the heater for a few moment...

Страница 12: ...trol valve needs to be replaced 7 Loose wire on tip over switch 8 Loose or broken wire 9 Loose mis located thermocouple 10 Defective thermo couple 11 Defective control valve 1 Open the gas valve 2 Rep...

Страница 13: ...ing compressed air where possible Blow air across the burner face until all dust has been dislodged from the surface 5 If the hose shows evidence of excessive abrasion or wear or if the hose is cut it...

Страница 14: ...S 1 Guard assembly 11 Piezo igniter kit 2 Thermocouple protector 12 Hose regulator assembly 3 Reflector assembly 13 On off Knob 4 Ignitor electrode 14 Inlet connection 5 Rear guard assembly 15 On off...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: