Страница 1: ...Generator Model G700 0600 Part Number 8010010 Operating Maintenance Instructions ...

Страница 2: ...Tel 0208 988 7400 Parts and Service Fax 0208 558 3622 or email as follows Parts Parts clarkeinternational com Service Service clarkeinternational com If you have any problems using or setting up your Generator call the Clarke Helpline on 0208 988 7400 Press 1 for Parts 2 for Technical Assistance Copyright Clarke International All rights reserved June 2000 ...

Страница 3: ...tions This is for your own safety and that of others around you and also to ensure the Generator provides you with long and trouble free service Guarantee This product is guaranteed against faults in manufacture for 12 months from purchase date Keep your receipt as proof of purchase This guarantee is invalid if the product has been abused or tampered with in any way or not used for the purpose for...

Страница 4: ... a well ventilated area Never overfill the tank fill to the level specified see page 6 Never smoke whilst refuelling and avoid smoking or using a naked flame near the generator Never start the engine if there is spilled fuel Any spillage must be wiped clean and the generator allowed to dry before attempting to start the engine Prevention of Electric Shock Always store the generator undercover when...

Страница 5: ...ect to any other electrical source 4 Positioning the Generator for use Always leave a least a 1M gap between the generator and any surrounding building or structures Always ensure the generator is on a solid flat surface Always ensure the surrounding area is free from any material that could burn or be damaged by heat Never move or tilt the generator whilst it is switched on Never cover the genera...

Страница 6: ...gine ON OFF 5 DC Reset Switch AC Trip Indicator AC Reset Switch DC Connector AC Connector 1 Carrying Handle 2 Fuel Cap 3 Fuel Tank 4 Alternator 5 Control Panel 6 Air Inlet Cover 7 Engine Control 8 Recoil Starter 9 Fuel Tap 10 Spark Plug 11 Exhaust 12 Exhaust Outlet ...

Страница 7: ...r stopping the engine suddenly with a load connected could cause serious damage WARNING allow the unit to cool down before refuelling 6 Fill Level 1 2 3 4 Fig 2 Use Clarke 2 stroke oil Part No 5060260 Before using your generator check that 1 The Generator unit is in good condition and free from any damage 2 The Generator Unit is clean and free from fuel or oil spillage 3 The Generator Unit is corr...

Страница 8: ...sition is indicated by the symbol Fig 5 2 Pull the Recoil Starter as shown in fig 6 Note To start the engine pull the recoil Starter slowly until you feel full resistance then pull briskly to turn the engine over The engine should start after no more than three or four pulls If the engine does not start see Troubleshooting 4 Switch the Ignition ON by pushing the rocker switch shown in fig 5 so tha...

Страница 9: ...circuit is overloaded the circuit protection switch will be tripped To reset the circuit press the DC reset switch 5 DC Reset Switch AC Trip Indicator AC Reset Switch DC Connector AC Connector IMPORTANT Never switch off the engine whilst an electrical device is connected Shutting down the Generator Switch off the electrical device Unplug the device from the generator Switch the Engine OFF see page...

Страница 10: ...cover 6 If the filter has become soiled clean as stated below If the filter is damaged or has become clogged replace Empty the fuel 3 tank described on page 8 Unbolt the fuel tap 9 from the tank and unscrew the shouldered bolt from the tap to remove the filter Wash thoroughly with soapy water rinse thoroughly and allow to dry completely before reassembling Replace fuel tap 9 and refit tank 3 If th...

Страница 11: ...ing The Engine 10 PLUG GAP 0 7 0 8mm 0 028 0 031 Remedy 1 Tighten spark plug 2 Tighten cyl head bolt 3 Replace gasket 4 Pull recoil starter harply 5 Clean fuel tank 6 Clean fuel line 7 Fill fuel tank 8 Open fuel tap 9 Clean spark plug 10 Replace spark plug 11 Contact Clarke Service Department 12 Check fuel 13 Contact Clarke Service Department Problem Will not Start Will not start or Low output Err...

Страница 12: ...k connection and or replace lead 3 Contact Clarke Servicing 4 Contact Clarke Servicing 1 Set Engine RPM 2 Contact Clarke Servicing Problem AC Indicator Light on No AC Output No DC Output Erratic Supply Possible Cause Tripped Circuit Breaker Poor connection or faulty lead Broken AC connector Faulty Circuit Breaker Tripped Circuit Breaker Poor connection or faulty lead Broken DC connector Faulty Cir...

Страница 13: ...pprox Cooling System Forced Air Cooling Stroke Bore 45x40mm Carburettor Type HG63 Air Cleaner Sponge Element Fuel Oil Mix Ratio 50 1 Compression Ratio 6 1 Generator Type Brushless Single Phase Peak Power 800Watt Rated Power 650 Watt Rated Rotation Speed 3000 RPM AC Rated Voltage 230 Volts AC Rated Frequency 50 Hz Maximum Output 3 2 Amps DC Rated Voltage 12Volts For Battery Charging ONLY DC Rated C...

Страница 14: ...Spare Parts Diagram fig 7 13 ...

Страница 15: ... HT70016 17 Gasket HT70017 18 Seal Ring HT70018 19 Air Filter Cover HT70019 20 Conrol Panel HT70020 21 AC Socket HT70021 22 DC Socket HT70022 23 AC Trip Switch HT70023 24 Indicator Lamp HT70024 25 DC Trip Switch HT70025 26 Cover Plate HT70026 27 Capacitor HT70027 28 Alternator Cover HT70028 29 Stator HT70029 30 Rotor HT70030 31 Front Cap HT70031 32 Rectifier HT70032 33 Screw M6x12 HT70033 34 Screw...