22
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The generator fails
to start
Ignition switch is off
Set the ignition switch to ‘on’
Not enough oil in the
generator
Add more oil, See page 11
No fuel
Add more fuel, See page 12
Spark plugs not working
correctly
Change the spark plugs, See
page 19
The generator fails
to generate
electricity
The device you are trying to
power is faulty
Make sure the device you want to
power is working properly
The AC breaker has activated Press the AC overload reset button
The generator is
difficult to start
The air filter is dirty
Clean the air filter, See page 20
The fuel filter is dirty
Clean the fuel filter, See page 21
If this does not solve your problem, please contact the Clarke service
department. See page 25