Clarke CSE400A Скачать руководство пользователя страница 3

3

ELECTRICAL CONNECTIONS

Their mains lead should be connected to a standard 230Volt (50Hz) electrical supply through
an approved plug or a suitably fused isolator switch. We strongly recommend that these
pumps be fitted with a Residual Current Device (RCD).

NOTE: This is MANDATORY when pump is used for pumping swimming pools and ponds

If the pump is to be connected to an outdoor electrical supply, make sure that both the
plug and the socket are of a BS approved waterproof design.

In the event that the pump is hard wired into the electrical system, it must be carried out in
accordance with IEE regulations.

If used for draining swimming pools or ponds, the pump MUST be fitted with a Residual
Current Device (RCD), with a rated residual operating current of no greater than 30mA.

WARNING: THIS APPLIANCE MUST BE EARTHED

IMPORTANT:

 The wires in the mains lead are coloured in accordance with the following

code:

Green & Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this appliance may not correspond with the coloured
markings identifying terminals in your plug proceed as follows:

Connect GREEN & YELLOW cord to plug terminal marked with a letter “E” or
Earth symbol “     ” or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter “L” or coloured RED

Connect BLUE cord to terminal marked with a letter “N” or coloured BLACK

FUSE RATING

The fuse in the plug for this appliance must be rated at 

13 amps

.

If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-
rewirable) please note:

1.

The plug must be thrown away if it is cut from the electric cable. There is a danger of
electric shock if it is subsequently inserted into a socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer or most electrical
outlets

5.

The fuse in the plug must be replaced with one of the same rating (

13 amps

) and

this replacement must be ASTA approved to BS1362.

IMPORTANT:

If you are in any doubt regarding electrical installation,

you should consult a qualified electrician.

Содержание CSE400A

Страница 1: ...Part No 7231100 SUBMERSIBLE WATER PUMP OPERATING MAINTENANCE INSTRUCTIONS SUBMERSIBLE WATER PUMP Model Nos CSE400A 0301 SUBMERSIBLE WATER PUMP...

Страница 2: ...ts Please note that dismantling this pump will invalidate the guarantee SAFETY PRECAUTIONS 1 These pumps are designed to pump WATER ONLY NEVER use for pumping flammable liquids or chemicals of any kin...

Страница 3: ...spond with the coloured markings identifying terminals in your plug proceed as follows Connect GREEN YELLOW cord to plug terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN YELL...

Страница 4: ...erged is 8 Metres This pump is suitable for permanent or semi permanent installations e g installations where it is necessary to maintain a water at a particular level As the water level rises so will...

Страница 5: ...must be placed in a vertical position on a solid flat surface If this is not available sit the pump on house bricks or something similar and ensure that this type of support is not likely to shift Th...

Страница 6: ...r contact the CLARKE Service Department on 0208 8988 7440 If the pump becomes badly clogged back flush by removing the outlet hose adapter and directing a jet of clean water through the outlet port 6...

Страница 7: ...Part No 7231100 Diameter x Height not including outlet SPECIFICATIONS PARTS SERVICE TEL 020 8988 7400 PARTS SERVICE FAX 020 8558 3622 or e mail as follows PARTS Parts clarkeinternational com SERVICE...