OPERATION

Plug the transformer into the power supply and switch the power ON. Switch the
lamp ON by pushing the rocker switch on the switch box ‘I’. Switch OFF by pushing
‘O’.

Ensure all air connections are secure, and the pick up is correctly located beneath
the grid, before filling the cabinet with abrasive media. Do not fill higher than the
level of the grid.

NOTE:
PTFE tape is provided which may be used on the threads of the various connectors
to ensure an airtight connection.

Select the ceramic abrasive nozzle to produce the jet required for the abrasive
media being used, and assemble according to the instructions given below.

Place the object to be cleaned in the cabinet, and close the lid, securing with the
two swivel clips.

If you are using a vacuum extraction device, turn it on before turning on the air
supply. Set the pressure to the required value, but not higher than 100lbf/in

2

, and

check to ensure there are no air leaks. Should there be any, turn off the air supply
and repair where necessary, before turning the supply back on. Pull the trigger on
the gun and proceed to blast the object to be cleaned.

Keep the jet facing the object and away from the clear plastic lid. Do not allow
the jet to train on the rubber gloves, the air hose within the cabinet or the fluorescent
lamp.

When completed, turn off the air supply first, and, as a precautionary measure,
pull the trigger before opening the lid.

6

Replace the grid, ensuring the feet face
downwards with the cut away section at
the right hand rear of the cabinet. The
pick up hose should be routed throught
the gap made by the cut away portion
of the grid.

Insert  the circular foam filter into the recess
in the Air Vent Cover, and attach the cover
to the rear of the cabinet as shown in Fig.4,
having first prised out  the plastic bung from
the vent hole.

Fig.4

Replacing the Abrasive Nozzle

NOTES:

T

here are no hard or fast rules governing nozzle sizes and air pressures used with

different abrasives. With experience and experimentation you will quickly learn
the best combinations for the required result.

On more delicate parts, start with minimal air pressure to avoid unnecessary
peening or excessive abrasion, and work up to a setting to produce the desired
finish.

Should any abrasive be spilled, ensure it is cleaned up immediately, as its slippery
properties can be extremely hazardous.

Ensure the air supply is disconnected before performing this operation.

1.

Pull the trigger of the gun as a precautionary measure.

2.

Unscrew the End Cap and withdraw the ceramic nozzle.

3.

Replace with the nozzle of your choice and carefully thread the end cap
back on to the gun, taking great care NOT to cross thread the fine thread.

NOTE:
Should it be necessary to change the Air Nozzle, first remove the abrasive nozzle
as described above. An box spanner will be required to unscrew and withdraw
the air nozzle.

Finally, connect the air supply to the extended
nut shown in Fig.5. Use of the PTFE tape supplied
with ensure an airtight seal.

The air supply should be dry, and capable of
delivering a minimum of 10 cuft/min at 100 lbf/in

2

Fig.5

Fig.6

Содержание CSB20B

Страница 1: ...SHOT BLAST CABINET MODEL No CSB20B Part No 7640110 OPERATING MAINTENANCE INSTRUCTIONS 1001 SHOT BLAST CABINET ...

Страница 2: ...34 35 Adapter Nut HTCSB2035 36 Gun 3 HTCSB2036 37 O Ring HTCSB2037 38 Plug HTCSB2038 39 Adapter HTCSB2039 40 Abrasive Pickup HTCSB2040 41 Worm Drive Clip HTCSB2041 42 Grid Foot HTCSB2042 10 1 Grid HTCSB2001 2 Flourescent Tube 12V HTCSB2002 3 End Connector HTCSB2003 4 Plastic cover HTCSB2004 5 Input Cable Assy 1 HTCSB2005 6 Cable Gland assembly HTCSB2006 7 Power Cable Assembly 2 HTCSB2007 8 Main Fi...

Страница 3: ...for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not affect yo...

Страница 4: ...g the use of air compressors and observe all necessary precautions when using compressed air SAFETY PRECAUTIONS Ensure you comply with all precautions concerning the use of air compressors and compressed air Ensure all air connections are secure Do Not use the machine if the rubber gloves are ripped or otherwise unserviceable Ensure the clear plastic lid is firmly secured before pressing the trigg...

Страница 5: ...red by a plastic sheath to one of the pins at the cable input end Assemble in reverse order ensuring the wires are correctly held by the plastic sheath at one end and the end connector at the other with the reflector correctly in position Replace the assembly into its retaining clips and test its operation by plugging the transformer in to the mains ASSEMBLY ref Fig 1 Carefully unpack the unit and...

Страница 6: ...face downwards with the cut away section at the right hand rear of the cabinet The pick up hose should be routed throught the gap made by the cut away portion of the grid Insert the circular foam filter into the recess in the Air Vent Cover and attach the cover to the rear of the cabinet as shown in Fig 4 having first prised out the plastic bung from the vent hole Fig 4 Replacing the Abrasive Nozz...

Отзывы: