11
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
Your sander has been designed to operate over a long period of time with a
minimum of maintenance. Continuous satisfactory operation depends upon
proper care.
Regularly clean the ventilation slots using a soft dry brush or dry cloth. Only
clean the motor housing using a clean damp cloth. Do not use any abrasive
or solvent-based cleaner.
A damaged power cable should be replaced by your CLARKE dealer or
qualified electrician.
The bearings in this sander are sealed for life and require no maintenance.
FAULTFINDING
SANDER IS OVERHEATING
This indicates the machine is dirty. Clean the ventilation holes, and blow out
with compressed air. Always wear eye protection when using compressed air
Overloading the machine will also cause overheating. Do not use for heavy
duty work and do not apply heavy pressure.
EXCESSIVE SPARKING OCCURS
This indicates worn brushes. This problem is quickly remedied but you should
consult your CLARKE dealer for parts and advice.
SANDER DOES NOT OPERATE WHEN SWITCHED ON
Check to ensure the fuse is sound and replace if necessary. If the fuse
is sound or blows repeatedly, consult your CLARKE dealer.
POOR ABRASION
If the sander is not removing material efficiently, check the sanding paper. If
the abrasive is worn down replace the paper. The paper must always be
stored in a dry place as if it allowed to become damp, the abrasive particles
will detach from the paper and will not abrade.
WARNING: BEFORE PERFORMING ANY MAINTENANCE, SWITCH OFF AND
UNPLUG THE SANDER.
Содержание CPS125
Страница 16: ......