Safety Precautions

•

These pumps are designed to pump 

Water Only

NEVER 

use for pumping flammable

liquids or chemicals of any kind.

•

ALWAYS 

ensure the pump is installed in a horizontal position with the outlet facing

vertically upwards, and that it is firmly anchored via its fixing screws.

•

ALWAYS 

ensure there is an adequate air flow around the pump. DO NOT mount it

in an enclosed atmosphere.

•

ALWAYS 

ensure all water pipes - supply or discharge, are adequately  supported

where necessary, so as not to put a strain on the pump connections.

•

ALWAYS 

ensure the inlet to the pump is completely unrestricted.

•

ALWAYS

 ensure the pump is protected from the elements, neither the motor nor the

electrical terminal box is intended to be waterproof.

•

ALWAYS 

ensure that all pipes are protected against damage where necessary,

and that they are suitably lagged to avoid the possibility of freezing during cold
weather.

•

ALWAYS 

disconnect the pump from the electrical supply before any cleaning or

maintenance of the pump.

•

NEVER

 allow the pump to run dry, as this will cause serious damage to the pump

seals.

•

NEVER

 switch the pump ON when a swimming pool etc, is in use, i.e., when there is

person or animal in the pool.

WARNING:

 As with all machinery, there are certain hazards involved with their operation
and use. Exercising respect and caution will considerably lessen the risk of
personal injury. However, if normal safety precautions are overlooked or ignored,
personal injury to the operator even damage to the pump or property, may
result. For your own safety and that of others around you, please read these
safety instructions in conjunction with the operating instructions, and before using
the pump.

Содержание CPE15S

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS 1002 MODEL NO CPE15S T 20S T 30S T PART No 7120203 4 7120205 6 7120207 8 CPE RANGE PUMPS CPE RANGE PUMPS...

Страница 2: ...ht to change specifications at any time without prior notice Always consult the machines data plate Contents Specifications 2 Guarantee 3 Safety Precautions 4 Water Connections 5 Electrical Connection...

Страница 3: ...S PH LPM HEAD M KG No CPE15S 1 1 230 1 325 17 14 0 7120203 CPE15T 1 1 400 3 325 17 14 0 7120204 Specifications CPE30S 3 3 230 1 800 18 15 5 7120207 CPE30T 3 3 400 3 800 18 15 5 7120208 CPE20S 2 2 230...

Страница 4: ...at of others around you and is also to help you achieve long and trouble free service from your new tool Your CLARKE CPE PUMP is a highly efficient robust continuously rated self priming pump with a p...

Страница 5: ...ensure that all pipes are protected against damage where necessary and that they are suitably lagged to avoid the possibility of freezing during cold weather ALWAYS disconnect the pump from the elect...

Страница 6: ...o as to retain water in the suction system and more importantly to prevent the possibility of large foreign objects entering the pump body The performance of your pump will be affected by the diameter...

Страница 7: ...the wires should be wired up in accordance with the following colour code Green Yellow Earth or marked with a letter E or Earth symbol Blue Neutral or terminal marked with a letter N Brown Live or ter...

Страница 8: ...ins supply 1 Check fuse replace if necessary Check fuse rating 2 Impeller seized blocked 2 Disconnect pump from mains investigate cause and clear blockage etc Pump runs but no output 1 Air in pump hou...

Страница 9: ...PARTS DIAGRAM CPE15 9...

Страница 10: ...4x16 1 16 GMF458 Pump Body 1 17 GMF501 Impeller 1 18 GM5114 Rear motor Cover 1 19 GM5119 Elastic Washer 1 20 GM5293 Fan 1 21 GM5319 Fan Cover 1 22 GM5375 Bearing 1 23 GM5387 Motor Stator For CPE 15 A1...

Страница 11: ...11 PARTS DIAGRAM CPE20...

Страница 12: ...ce 1 15 GM7103 Nut 1 16 GM8612 Impeller 1 17 GMF156 Key 4x4x16 1 18 GM5465 Bearing 1 19 GM5466 Bearing 1 20 GM5503 Motor Bracket 1 21 GM6994 Condenser 30 For CPE 20 A1 1 22 GM6996 Elastic Washer 1 23...

Страница 13: ...13 PARTS DIAGRAM CPE30...

Страница 14: ...1 13 GM7103 Nut 1 14 GM8613 Impeller 1 15 GMF156 Key 4x4x16 1 16 GM5505 Motor Bracket 1 17 GM6321 Bearing 1 18 GM6854 Condenser 50 For CPE 30 A1 1 19 GM7187 Elastic washer 1 20 GM8010 Rear Motor Cover...

Отзывы: