Clarke CDM65 Скачать руководство пользователя страница 4

4

AC VOLTAGE DETECTION

1.

Set the selector switch to the AC WIRE position.

Calibration

2.

Hold the unit in the air away from any metal objects,

3.

Press and hold the TEST button.

• The unit will beep twice when calibration is complete.

Do not release the TEST button.

Using

4.

Keep holding the TEST button and place the unit on the
wall, slowly move the unit sideways across the wall.

• As you approach a live wire, the signal lights will light up

sequentiallly, the buzzer will sound when you reach the
edge of the live wire, when this happens mark the point
by placing a pencil mark in the grove on top of the unit.

5.

Carry on moving the unit in the same direction until all
of the signal LEDS go out and then reverse direction.

• Once again, mark the point at which the top LED lights

up and the buzzer sounds by placing a pencil mark in
the grove on top of the unit.

• The centre of the live wire is located mid way between

the two pencil marks.

Содержание CDM65

Страница 1: ...3 1 SUPER DETECTOR 3 1 SUPER DETECTOR OPERATING MAINTENANCE INSTRUCTIONS 1207 MODEL No CDM65 Part No 4500135...

Страница 2: ...st manufacturing faults for a period of 12 months from the date of purchase Keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered wit...

Страница 3: ...attery 1 Remove the battery door on the rear of the unit 2 Connect a 9V PP3 battery to the battery clip 3 Place the battery into the compartment 4 Replace the battery door Scan mode selector Power Ind...

Страница 4: ...s the wall As you approach a live wire the signal lights will light up sequentiallly the buzzer will sound when you reach the edge of the live wire when this happens mark the point by placing a pencil...

Страница 5: ...ill cause the detector to register a voltage over a wider area Rubbing or banging the wall may generate static electricity causing a false reading Touching a damp wall being tested may also cause a fa...

Страница 6: ...ll As you approach a metal object the signal lights will light up sequentiallly the buzzer will sound when you reach the edge of the metal object when this happens mark the point by placing a pencil m...

Страница 7: ...7 METAL DETECTION Notes Wearing rings or other hand jewellery may cause a false reading...

Страница 8: ...hen you reach the edge of the studding when this happens mark the point by placing a pencil mark in the grove on top of the unit 4 Carry on moving the unit in the same direction until all of the signa...

Страница 9: ...ll not work simply re calibrate the unit 150 mm away from the last place The surface of the wall should be dry and flat Always keep your free hand away from the wall during detection If you release th...

Страница 10: ...Take several readings vertically above below to the left and right to confirm the reading Detection Depths Iron Pipe 25mm 30 mm Studding 30 x 30mm 18 mm AC Voltage 90 250V 50 60 Hz 50 mm Detection dep...

Страница 11: ...ture 7o C To 40o C Do not dispose of this product with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic equipment at a recognised disposal...