TROUBLE SHOOTING CONTINUED
PROBLEM
: Unit is in laundry mode and will not manually change to any other
mode.
CAUSE:
(This condition can occur when the ambient temperature is below 10°C or is
above 35°C).
When the ambient temperature is below 10°C a protection device in your
dehumidifier will operate. This engages the electronic defrost program.
The unit will now only operate in dehumidifier mode with the fan speed at
high level. The compressor will operate intermittently by switching on for 40
minutes and switching off for 10 minutes. The mode cannot be changed until
the ambient temperature rises above 10°C. When the temperature is above
35°C this program will come into operation to protect the compressor from
overheating.
WARNING:
The use of spare parts or accessories, other than those supplied
by CLARKE international or one of its recognised dealers, may be
hazardous and could invalidate the guarantee.
PARTS LIST
ITEM:
DESCRIPTION:
PART NO:
1.
Air Filter .............................................................................. EH197001
2.
Active Carbon Filter ........................................................ EH197002
1