MAINTENANCE

DISASSEMBLY

The filter can be disassembled without removal from air line.

1. Shut OFF the inlet pressure and 

reduce pressure in the inlet and 
outlet lines to zero.

2. Remove the bowl. Push into the 

body and turn anti-clockwise.

3. Disassemble in general 

accordance with the parts 
illustrated. Do not remove the 
drains or the service indicators 
unless replacement is necessary. 
Remove and replace only if they malfunction or if converting to auto drain.

CLEANING

1. The element cannot be cleaned. Clean the polycarbonate bowl with 

warm water only. Do not submerge service indicator in water. Clean 
indicator with a dry, clean cloth. Clean other parts with warm soapy water.

2. Rinse and dry the parts. Blow out internal passages with clean, dry, 

compressed air. 

3. Replace any parts found to be damaged. Replace the plastic bowl with a 

metal bowl if the plastic bowl shows signs of cracking or cloudiness.

ASSEMBLY

1. Lubricate the o-rings, the portion of the manual drain body that contacts 

the bowl, and the hole in the manual drain body that accommodates the 
stem of the drain valve with o-ring grease.

2. Assemble the filter as shown on page 7. The arrows on the indicator and 

body must point in same direction. Torque values are listed below.

Torque Settings

Part 

Inch Pounds (N-m)

Screw (a)

17 to 22 (1.9 to 2.5)

Element

5 to 20 (0.5 to 2.3)

Screw (b)

25 to 35 (2.8 to 3.9)

Nut

20 to 25 (2.3 to 2.8)

Содержание CAT181

Страница 1: ...INSTALLATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0619 ISS 1 COALESCING AIR FILTER MODEL NO CAT181 PART NO 3120198...

Страница 2: ...to give long and trouble free service If however having followed the instructions in this booklet carefully you encounter problems consult your local CLARKE dealer SPECIFICATION GENERAL SAFETY RULES...

Страница 3: ...e 6 Keep the flexible air supply hose away from heat oil and sharp edges 7 Avoid damaging the components for example by applying excessive force of any kind 8 Always maintain any air tool to be used w...

Страница 4: ...faster wear and is a possible safety hazard INSTALLATION 1 Ensure the compressor is turned off Before using the airline drain water from the air reservoir at the compressor 2 The filter should be ins...

Страница 5: ...c Contact your CLARKE dealer for further information or CLARKE International Service Department USE AND CARE IN SERVICE 1 Let the filter run with the air supply on Ensure that the pressure to the air...

Страница 6: ...water only Do not submerge service indicator in water Clean indicator with a dry clean cloth Clean other parts with warm soapy water 2 Rinse and dry the parts Blow out internal passages with clean dr...

Страница 7: ...onal com PARTS LIST DIAGRAM No Description No Description 1 Polycarbonate bowl assembly 6 Element O ring 2 Metal bowl and O ring 7 Sight glass Kit 3 Service Indicator Assembly 8 O Ring for polycarbona...

Страница 8: ......

Отзывы: