12
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
STORAGE
If the tool is to be stored, or is idle for longer than 24 hours, run a few drops of
Clarke air line oil into the air inlet, and run the tool for 5 seconds in order to
lubricate the internal parts. Store the tool safely in its box in a dry, secure
environment.
When storing, ensure the blanking plug is replaced on the airline connector
once the airline has been disconnected.
**Clarke Airline Oil is available from your Clarke dealer: Part no 3050825.
SYMPTOM
PROBLEM
SOLUTION
Tool runs at normal
speed but slows down
under any load.
1. Air motor parts worn.
2. Worn or sticking
mechanism due to
lack of lubricant.
1. Return to Clarke dealer
for repair.
2. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
Tool runs slowly. Air flows
weakly from exhaust.
1. Air motor parts
jammed with gum/
dirt.
2. Air-line regulator in
closed position.
3. General airflow
blocked by dirt.
1. Examine inlet air filter for
blockage. Drip a few
drops of air tool lubricat-
ing oil into air inlet.
2. Adjust in-line regulator to
open position.
3. Operate tool in short
bursts.
Tool will not run. Air flows
freely from exhaust.
1. Air motor vanes stuck
due to buildup of
foreign material.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.
Tool will not shut off.
1. Throttle O-rings
damaged or ill-fitting
in seat.
1. Return to Clarke dealer
for repair.
Содержание CAT154