background image

11

Employers are advised to refer to the HSE publication “Guide for Employers”.

All hand held power tools vibrate to some extent, and this vibration is transmitted to the
operator via the handle, or hand used to steady the tool.  Vibration from about 2 to 1500
herz is potentially damaging and is most hazardous in the range from about 5 to 20 herz.

Operators who are regularly exposed to vibration may suffer from Hand Arm Vibration
Syndrome (HAVS), which includes ‘dead hand’, ‘dead finger’, and ‘white finger’.  These
are painful conditions and are widespread in industries where vibrating tools are used.

The health risk depends upon the vibration level and the length of time of exposure to
it……in effect, a daily vibration dose.

Tools are tested using specialised equipment, to approximate the vibration level generated
under normal, acceptable operating conditions for the tool in question.  For example, a
grinder used at 45° on mild steel plate, or a sander on softwood in a horizontal plane etc.

These tests produce a value‘

a’, expressed in metres per second per second, which

represents the average vibration level of all tests taken, in three axes where necessary,
and a second figure ‘K’, which represents the uncertainty factor, i.e. a value in excess of
‘a’, to which the tool could vibrate under normal conditions. These values appear in the
declaration on page 2.

HAND-ARM VIBRATION

You will note that a third value is given in the specification - the highest measured reading
in a single plane. This is the maximum level of vibration measured during testing in one of
the axes, and this should also be taken into account when making a risk assessment.

a’ values in excess of 2.5 m/s2 are considered hazardous when used for prolonged periods.

A tool with a vibration value of 2.8 m/s

2

 may be used for up to 8 hours (cumulative) per

day, whereas a tool with a value of 11.2 m/s

2

 may be used for ½ hour per day only.

The graph below shows the vibration value against the maximum time the respective
tool may be used, per day.

The uncertainty factor should
also be taken into account
when assessing a risk. The two
figures ‘

a’ and ‘K’may be

added together and the
resulant value used to assess the
risk.

It should be noted that if a tool
is used under abnor mal, or
unusual conditions, then the
vibration level could possibly
increase significantly.  Users must
always take this into account
and make their own risk
assessment, using the graph as
a reference.

Some tools with a high vibration value, such as impact wrenches, are generally used for
a few seconds at a time, therefore the cumulative time may only be in the order of a few
minutes per day.  Nevertheless, the cumulative effect, particularly when added to that
of other hand held power tools that may be used, must always be taken into account
when the total daily dose rate is determined.

Содержание air CAT101

Страница 1: ...1 2 IMPACT WRENCH 1 2 IMPACT WRENCH MODEL No CAT101 Part No 3110857 OPERATION MAINTENANCE INSTRUCTIONS 0707 ...

Страница 2: ...at any time without prior notice Always consult the machine s data plate GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty...

Страница 3: ...ay alert and use common sense Do not operate the impact wrench when you are tired or under the influence of alcohol drugs or medication Always wear eye protectors when using the impact wrench Eye protectors must provide protection from flying particles from the front and the side Always wear ear protectors when using the impact wrench Do not overreach Keep proper footing and balance at all times N...

Страница 4: ...could fail due to vibration DO NOT force or misuse the tool It will do a better and safer job at the rate for which it was designed DO NOT remove any labels Damaged labels should be replaced This tool vibrates with use Vibration may be harmful to your hands or arms Stop using the tool if discomfort a tingling feeling or pain occurs Seek medical advice before resuming use NEVER use standard sockets...

Страница 5: ...lated compressed air as a power source for the impact wrench Air compressors used with the impact wrench must comply with the appropriate European Community safety directives A build up of moisture or oil in the air compressor will accelerate wear and corrosion in the impact wrench Never exceed the maximum operating pressure for the impact wrench AIR HOSE The air hose must be rated at least 150 of...

Страница 6: ... 2 Connect the other end of the hose to the compressor 3 Your impact wrench is now ready for use You can fit a whip hose with a quick fit coupling if required available from your Clarke dealer WARNING COMPRESSED AIR CAN BE DANGEROUS ENSURE THAT YOU ARE THOROUGHLY FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF COMPRESSORS AND COMPRESSED AIR SUPPLY ...

Страница 7: ...pact wrench should be operated in the forward F direction 2 For loosening the impact wrench should be operated in the reverse R direction Direction control button in forward position Direction control button in reverse position FITTING THE IMPACT SOCKET 1 Select the impact socket you require WARNING NEVER use standard sockets These may shatter with serious consequences Use ONLY Impact sockets 2 Pu...

Страница 8: ... Refer to the compressor instruction book for the procedures to shut down and release the compressed air 2 Once the pressure has been released disconnect the air supply hose from the impact wrench 3 Store the impact wrench safely in its box in a dry secure environment Squeeze OPERATING THE IMPACT WRENCH 1 Locate the socket over the nut to be tightened or loosened 2 Squeeze the trigger to start the...

Страница 9: ...f the impact wrench CLEANING Keep the body of the impact wrench clean and free from debris Grit or gum deposits in the tool may reduce efficiency SERVICE AND REPAIR All servicing and repair must be carried out by qualified service technicians NOTES Please note that factors other than the tool may effect its operation and efficiency such as reduced compressor output excessive drain on the airline m...

Страница 10: ...Anvil 19 KL504W19 Hammer Cage 20 KL504W20 Hammer Pin 21 KL504W21 Hammer Dog 22 KL504W22 Drive Cam 23 KLSP008 Pin 24 KL504W24 Cylinder 25 KL504W25 Rotor 26 KL504W26 Rotor Blade 27 KL504W27 Rear End Plate 28 KLCA6001 Ball Bearing 29 KL504W29 Front End Plate 30 KLSP006 Pin 31 KL504W31 Spring 32 KL504W32 Pin 33 KL504W33 Gasket 34 KL504W34 Rear Cover 35 KLSH0031 Screw Spring Washer 36 KL504W37 Front Ru...

Страница 11: ...values appear in the declaration on page 2 HAND ARM VIBRATION You will note that a third value is given in the specification the highest measured reading in a single plane This is the maximum level of vibration measured during testing in one of the axes and this should also be taken into account when making a risk assessment a values in excess of 2 5 m s2 are considered hazardous when used for pro...

Страница 12: ......

Отзывы: