Transporting the Generator Set
DO NOT transport the generator set with a gas bottle connected.
Ensure the ignition switch is OFF.
Transport in a horizontal position and if transported in the back of a truck or van, ensure it is
adequately secured to prevent it from being damaged by sliding around.
Storing for Extended Period.
Always store in a dry, clean environment, under cover, protected from the elements.
•
Remove the Spark Plug and pour a spoonful of engine oil into the cylinder. Gently pull
the starter cord to distribute the oil around the cylinder, stopping the piston at its highest
point on the compression stroke.
•
Replace the spark plug.
•
Change the engine oil (see page 13)
TROUBLESHOOTING
Should you experience difficulties other than those outlined here, you should consult your
Clarke dealer.
14
Remedy
1.
Switch to ON
2.
Turn ON gas
3.
Renew gas bottle
4.
Contact your Clarke
Dealer or Clarke Service.
5.
Pull more sharply
6.
Disconnect all
appliances
7.
Top up engine oil
8.
Tighten/clean spark plug
9.
Re-Prime system
1.
Clean/replace air
cleaner element
2.
See page 9, para (ii)
1.
Wait until the generator
has cooled sufficiently
then press the Reset
button
2.
Investigate and rectify
3.
Select correct position.
Problem
Engine will not Start
Difficult to start or Low
output
No Current Output.
Probable Cause
1.
Ignition switch is OFF
2.
Gas turned OFF
3.
Gas bottle empty
4.
Faulty gas regulator/
controller
5.
Insufficient starting pull
6.
Electrical appliances are
connected to the
generator outlets
7.
Engine oil level is low
8.
Loose/faulty spark plug
9.
Insufficient Gas
1.
Air Cleaner dirty
2.
Extreme operating
conditions
1.
The Thermal circuit
breaker has intervened.
2.
The equipment
connected to the
generator is faulty
3.
110/230V selector in
wrong position.
Содержание 8852005